Toshiba RAV-GM1601ATP-E (TR) Service Manual page 64

Outdoor unit digital inverter
Hide thumbs Also See for RAV-GM1601ATP-E (TR):
Table of Contents

Advertisement

Check
Outdoor
code
LED display
[F15]
[F31]
[H01]
(Item without special mention Indicates part of outdoor unit.)
[Miswiring of heat exchanger sensor (TE, TS)]
Is mounting status of
TE and TS sensors correct?
YES
Is connection of CN600 correct?
Is resistance value of TS sensor correct?
YES
Is connection of CN601 correct?
Is resistance value of TE sensor correct?
YES
Check outdoor P.C. board.
Failure → Replace
[EEPROM trouble]
Check outdoor P.C. board.
Failure → Replace
[Compressor break down]
Is power supply voltage normal?
AC198 to 264V
YES
Is wire connection correct?
Compressor lead
(P.C. board side, Compressor side),
Reactor lead, Power supply lead
YES
Does an abnormal overload happen?
YES
Check outdoor P.C. board.
Failure → Replace
* When replacing outdoor P.C.board, replace
the fuse.
Check and troubleshooting
NO
NO
NO
NO
NO
NO
- 64 -
Correct sensor mounting.
Correct connector.
Replace TS sensor
Correct connector.
Replace TE sensor
Correct power supply line.
Check wire connection
and correct it.
Remove and improve
the cause of overload.