4. Configuring the Fail Safe/Fail Secure and RX* DIP switch settings:
Please note that the lock must be cycled once in order for setting changes to take effect.
5. Install Lock Body into Door:
a. Plug mortise lock harness into
ElectroLynx
Important: Door must remain open during
installation. Use door stop.
b.
Install, but do not tighten two #12 x 1"
combination screws through lock body
(Fig. 5).
6) Installation Instructions (Contin
harness in door (Fig. 5).
®
Check polarity:
Verify + (red) wire
Fig. 5
8
ued)
*RX output only configurable for locks
with end-of-line resistance monitoring.
Default is normally open.
Outside Face of Door