Fujitsu AS G07KGTA Series Service Instruction page 68

Split type room air conditioner, wall mounted type inverter
Table of Contents

Advertisement

Room temperature control for indoor unit sensor
Depending on the installed environment, correction of the room temperature sensor may be re-
quired. Select the appropriate control setting according to the installed environment.
The temperature correction values show the difference from the Standard setting "00" (manufactur-
er's recommended value).
Function number
30
(For cooling)
(For heating)
Room temperature control for wired remote controller sensor
Depending on the installed environment, correction of the wire remote temperature sensor may be
required. Select the appropriate control setting according to the installed environment.
To change this setting, set Function 42 to Both "01".
Ensure that the Thermo Sensor icon is displayed on the remote controller screen.
Function number
35
(For cooling)
(For heating)
Setting value
00
01
02
03
04
05
06
07
08
31
09
10
11
12
13
14
15
16
17
Setting value
00
01
02
03
04
05
06
07
08
36
09
10
11
12
13
14
15
16
17
Setting description
Standard setting
No correction 0.0 °C
-0.5 °C
-1.0 °C
-1.5 °C
-2.0 °C
-2.5 °C
-3.0 °C
-3.5 °C
-4.0 °C
+0.5 °C
+1.0 °C
+1.5 °C
+2.0 °C
+2.5 °C
+3.0 °C
+3.5 °C
+4.0 °C
Setting description
No correction
No correction 0.0°C
-0.5 °C
-1.0 °C
-1.5 °C
-2.0 °C
-2.5 °C
-3.0 °C
-3.5 °C
-4.0 °C
+0.5 °C
+1.0 °C
+1.5 °C
+2.0 °C
+2.5 °C
+3.0 °C
+3.5 °C
+4.0 °C
03-02
Factory
setting
More cooling
Less heating
Less cooling
More heating
Factory
setting
More cooling
Less heating
Less cooling
More heating

Hide quick links: