AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LMCA AS G09LMCA AS G12LMCA AS G14LMCA OUTDOOR AO G07LMCA AO G14LMCA AO G09LMCA AO G12LMCA...
Page 2
1. INDOOR UNIT WALL MOUNTED TYPE : ASG07LMCA ASG09LMCA ASG12LMCA ASG14LMCA DTR_AS076E_05 2015.01.16...
FEATURES MODELS ASG07LMCA / AOG07LMCA ASG09LMCA / AOG09LMCA ASG12LMCA / AOG12LMCA ASG14LMCA / AOG14LMCA AO G07LMCA AO G14LMCA AO G09LMCA AO G12LMCA FEATURES Energy efficiency class MODEL AS G07LMCA AS G09LMCA AS ...
10°C HEAT Operation The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied. NOTE: • When the room temperature is higher than 10°C, “10°C HEAT” operation will not start. Operation starts and maintains the room temperature at 10°C when the temperature drops below 10°C.
Conditions: Fan speed: HIGH Operation mode: FAN 7-1. AIR VELOCITY DISTRIBUTION MODELS :ASG07LMCA, ASG09LMCA, ASG12LMCA Unit : m/s TOP VIEW Vertical flap: Up Horizontal flap: Center Unit : m/s TOP VIEW Vertical flap: Up Horizontal flap: Right & Left...
Page 16
Conditions: Fan speed: HIGH MODEL : ASG14LMCA Operation mode: FAN Unit : m/s TOP VIEW Vertical flap: Up Horizontal flap: Center Unit : m/s TOP VIEW Vertical flap: Up Horizontal flap: Right & Left Unit : m/s SIDE VIEW Vertical flap: Up Horizontal flap: Center Unit : m/s...
7-2. AIR FLOW MODELS :ASG07LMCA, ASG09LMCA, ASG12LMCA Cooling Number of Fan speed rotations Air flow (r.p.m.) HIGH 1320 1160 QUIET Heating Number of Fan speed rotations Air flow (r.p.m.) HIGH 1320 1160 QUIET - (01 - 14) -...
Page 18
MODEL : ASG14LMCA Cooling Number of Fan speed rotations Air flow (r.p.m.) HIGH 1360 1220 QUIET Heating Number of Fan speed rotations Air flow (r.p.m.) HIGH 1360 1220 1040 QUIET - (01 - 15) -...
2,000 2,000 4,000 4,000 8,000 8,000 Octave band center frequency,Hz Octave band center frequency,Hz Octave band center frequency,Hz Octave band center frequency,Hz MODEL : ASG09LMCA Cooling Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 HIGH...
ELECTRICAL CHARACTERISTICS Model name ASG07LMCA ASG09LMCA ASG12LMCA ASG14LMCA Voltage 230~ Power supply Frequency Max. operating current Connection cable Wiring spec. *1 Limited wiring length *1: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005. - (01 - 19) -...
SAFETY DEVICES Model ASG07LMCA Protection form ASG09LMCA ASG12LMCA ASG14LMCA Circuit protection Current fuse (PC board) 250V 3.15A OFF: 105 ± 10 °C Fan motor protection Thermal protector program ON: 90 ± 10 °C - (01 - 20) -...
EXTERNAL INPUT & OUTPUT Connector INPUT OUTPUT REMARKS Control input See external CNA01 CNB01 Operation status output input/output settings for details. CNB02 Error status output 11-1. EXTERNAL INPUT CONTROL INPUT (Operation/Stop or Forced stop) The air conditioner can be remotely operated by means of the following on-site work. "Operation/Stop"...
Page 25
When function setting is in "Forced stop" mode Input signal Forced stop Command Normal Operation Indoor unit Stop Remote controller Remote control operation invalidity Parts (Optional) Parts name Model name External connect kit UTY-XWZXZ5 Communication kit UTY-XCBXZ2 * For operating the EXTERNAL function, the wall mounted type requires the communication kit in addition to the wire (UTY-XWZXZ5).
11-2. EXTERNAL OUTPUT OPERATION STATUS OUTPUT An air conditioner operation status signal can be output. Circuit diagram example Indoor unit control PC board Communication kit Connected unit Connector 24V DC Ex.)Relay unit Ex.)Display Relay power supply *10 m Signal Optional parts Field supply...
Page 27
ERROR STATUS OUTPUT An air conditioner error status signal can be output. Circuit diagram example Indoor unit control PC board Communication kit Connected unit Connector 24V DC Ex.)Relay unit Ex.)Display Relay power supply *10 m Signal Optional parts Field supply *: Make the distance from the PC board to the connected unit within 10 m.
FUNCTION SETTINGS INDOOR UNIT (Setting by remote controller) 12-1. • The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings can cause the indoor unit to malfunction. •...
FUNCTION DETAILS Functions 1) Filter sign 2) Room temperature control for cooling 3) Room temperature control for heating 4) Auto restart 5) Room temperature sensor switching 6) Remote controller custom code 7) External input control 8) Room temperature sensor switching (Aux.) 9) Indoor unit fan control for energy saving for cooling 1) Filter sign Select appropriate intervals for displaying the filter sign on the indoor unit according to the...
Page 30
4) Auto restart Enable or disable automatic restart after a power interruption. ( ... Factory setting) Setting description Function number Setting value Enable Disable * Auto restart is an emergency function such as for power outage etc. Do not attempt to use this function in normal operation.
Page 31
9) Indoor unit fan control for energy saving for cooling Enables or disables the power-saving function by controlling the indoor unit fan rotation when the outdoor unit is stopped during cooling operation. ( ... Factory setting) Setting description Function number Setting value Disable Enable...
Page 32
REMOTE CONTROLLER CUSTOM CODE SETTING Use the following steps to select the custom code of the remote controller. (Note that the air conditioner cannot receive a signal if the right custom code has not been set.) Press the START/STOP button until only the clock is displayed on the remote controller display.
OPTIONAL PARTS 13-1. CONTROLLERS Exterior Parts name Model No. Summary Large and full-dot liquid crystal screen, wide and large keys Wired remote easy to press, user-intuitive UTY-RVNM controller arrow key. *Optional communication kit is necessary for installation. The room temperature can be controlled by detecting the Wired remote temperature accurately with...
SPECIFICATIONS INVERTER COOLING & HEATING Type Model name AOÛG07LMCA AOÛG09LMCA AOÛG12LMCA AOÛG14LMCA Power source 230 V~ 50 Hz Available voltage range 198-264 V Starting current Cooling 1,670 1,830 1,940 Air flow rate Heating 1,470 1,600 1,700 Type × Q'ty Propeller fan × 1...
DIMENSIONS MODELS :AOG07LMCA, AOG09LMCA, AOG12LMCA (Unit : mm) INSTALLATION PLACE CAUTION When the outdoor temperature is 0 °C or less, do not use the accessory drain pipe and drain cap. If the drain pipe and drain cap...
Page 38
MODEL : AOG14LMCA (Unit : mm) Top view Front view Side view Airflow Drain pipe 4-ø11.3mm hole mounting place (ø20) Bottom view INSTALLAT ION PLACE CAUTION When the outdoor temperature is 0 °C or less, do not use the accessory drain pipe and drain cap.
AIR FLOW MODELS :AOG07LMCA, AOG09LMCA Cooling Number of rotations Air flow (r.p.m.) 1670 Heating Number of rotations Air flow (r.p.m.) 1470 MODEL : AOG12LMCA Cooling Number of rotations Air flow (r.p.m.) 1830 1078 ...
Page 48
MODEL : AOG14LMCA Cooling Number of rotations Air flow (r.p.m.) 1940 1141 Heating Number of rotations Air flow (r.p.m.) 1700 1000 - (02 - 13) -...
ELECTRICAL CHARACTERISTICS Model name AOÛG07LMCA AOÛG09LMCA AOÛG12LMCA AOÛG14LMCA Voltage 230 ~ Power supply Frequency Max. operating current *1 10.5 Starting current Circuit breaker current Wiring spec. *2 Power cable *1: The maximum current is the total current of indoor unit and outdoor unit.
SAFETY DEVICES Model Protection form AOÛG07LMCA AOÛG09LMCA AOÛG14LMCA AOÛG12LMCA 250V 20A Current fuse Circuit protection (Main printed circuit board) 250V 3.15A 250V 5A OFF: 100 ± 15 °C OFF: 150 ± 15 °C Fan motor protection Terminal protection program ON: 95 ± 10 °C ON: 120 ±...