Fujitsu AS G07KGTA Series Service Instruction page 36

Split type room air conditioner, wall mounted type inverter
Table of Contents

Advertisement

Trouble shooting 7
INDOOR UNIT Error Method:
Connection unit number error (Indoor
unit Wired remote controller error)
Detective Actuators:
Wired remote controller ( 2-Wire )
Indoor unit Controller PCB circuit
Forecast of Cause : 1. Wrong wiring / Number of I.U, RC in RCgroup 2. Indoor unit controller PCB defective
Check Point 1 : Wire installation
Wrong number of connecting indoor unit
Check Point 2 : Check Indoor unit controller PCB
Check if controller PCB damage
Check if controller PCB and check the Error after setting remote controller address
Indicate or Display:
Outdoor Unit : No indication
Indoor Unit
: Operation lamp: 2 time Flash, Timer lamp: 9 time Flash
Economy lamp: Continuous flash.
ERROR CODE : [E : 29 ]
Detective details:
When the number of connecting indoor units are out of specified rule.
02-10

Hide quick links:

Advertisement

Table of Contents