Page 1
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LUCA AS G09LUCA AS G12LUCA AS G14LUCA OUTDOOR AO G07LUCA AO G12LUC AO G09LUCB AO G14LUC...
FEATURES MODEL ASG07LUCA / AOG07LUCA ASG09LUCA / AOG09LUCB ASG12LUCA / AOG12LUC ASG14LUCA / AOG14LUC AO G07LUCA AO G12LUC AO G09LUCB AO G14LUC FEATURES Energy efficiency class MODEL AS G07LUCA AS G09LUCA AS ...
Page 5
Outdoor unit low noise *Only available with Wireless RC. When air-conditioner operates in large capacity, operation noise of outdoor unit will be suppressed. In case of room temperature being close to setting temperature, operation noise might not decrease. Noise level Down Low noise Rated...
WIRELESS REMOTE CONTROLLER FEATURES 3 Mode timer setup (Weekly / Program / Sleep) are possible. Easy operation. Easy to change signal code (4 patterns) by button operation. Simple function setting Setting of the air conditioner selection function is performed by remote controller. Built-in timers ...
Page 7
FUNCTIONS Signal Transmitter MODE button FAN button 10 °C HEAT button ECONOMY button SWING button TEMP. OUTDOOR UNIT LOW button SET button NOISE button POWERFUL button TIMER SETTING button WEEKLY button START/STOP SEND button button ON/OFF button SLEEP button SELECT button RESET button NEXT button...
SPECIFICATIONS WALL MOUNTED Type INVERTER HEAT PUMP Model name AS G07LUCA AS G09LUCA AS G12LUCA AS G014LUCA Power source 230V~ 50Hz Available voltage range 198-264V~ 50Hz 2.00 2.50 3.50 4.20 Rated Btu/h 6,800 8,500 11,900 14,300 Cooling 0.5-3.0 0.5-3.2...
Page 9
Model name AS G07LUCA AS G09LUCA AS G12LUCA AS G014LUCA Cooling Energy efficiency class Heating (Average) Cooling 2.0 (35°C) 2.5 (35°C) 3.5 (35°C) 4.2 (35°C) Pdesign Heating (Average) 2.6 (-10°C) 2.8 (-10°C) 3.9 (-10°C) 4.8 (-10°C) SEER Cooling 7.20...
FAN PERFORMANCE 7-1. AIR VELOCITY DISTRIBUTION Note: Fan speed : High MODEL : ASG07LUCA Operation mode : FAN Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Center 0.75 Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Right &...
Page 16
Note: Fan speed : High MODEL : ASG09LUCA Operation mode : FAN Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Center Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Right & Left Unit : m/s SIDE VIEW Vertical flap : Up...
Page 17
Note: Fan speed : High MODEL : ASG12LUCA, ASG14LUCA Operation mode : FAN Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Center Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Right & Left Unit : m/s SIDE VIEW Vertical flap : Up...
7-2. AIR FLOW MODEL : ASG07LU CA Cooling Number of Fan speed rotations Air flow (r.p.m.) HIGH 1140 1050 QUIET Heating Number of Fan speed rotations Air flow (r.p.m.) HIGH 1180 1050 QUIET - (01 - 15) -...
Page 19
MODEL : ASG09LU CA Cooling Number of Fan speed rotations Air flow (r.p.m.) HIGH 1300 1080 QUIET Heating Number of Fan speed rotations Air flow (r.p.m.) HIGH 1300 1120 QUIET - (01 - 16) -...
Page 20
MODEL : ASG12LU CA Cooling Number of Fan speed rotations Air flow (r.p.m.) HIGH 1370 1120 QUIET Heating Number of Fan speed rotations Air flow (r.p.m.) HIGH 1370 1180 QUIET - (01 - 17) -...
Page 21
MODEL : ASG14LU CA Cooling Number of Fan speed rotations Air flow (r.p.m.) HIGH 1370 1220 QUIET Heating Number of Fan speed rotations Air flow (r.p.m.) HIGH 1510 1220 1030 QUIET - (01 - 18) -...
ELECTRIC CHARACTERISTICS Model name ASG07LUCA ASG09LUCA ASG12LUCA ASG14LUCA Voltage 230~ Power supply Frequency Max. operating current Connection cable 1.0-1.5 *1)Wiring Spec. Limited wiring length *1) Wiring Spec. Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E0005) - (01 - 22) -...
SAFETY DEVICES Model ASG07LUCA Protection form ASG09LUCA ASG12LUCA ASG14LUCA Circuit protection Current fuse (PCB) 250V 3.15A Terminal protection Current (thermal) fuse 250V 3A OFF: 160 ± 25 °C Fan motor protection Thermal protector program ON: 110 ± 25 °C - (01 - 23) -...
EXTERNAL INPUT & OUTPUT Connector INPUT OUTPUT REMARKS CNA01 Control input See external CNB01 Operation status output input/output settings for details. CNB02 Error status output 11-1. EXTERNAL INPUT CONTROL INPUT (Operation/Stop or Forced stop) The air conditioner can be remotely operated by means of the following on-site work. "Operation/Stop"...
Page 28
When function setting is "Forced stop" mode Input signal Forced stop Command Normal Operation Indoor unit Stop Remote controller Remote control operation invalidity Parts (Optional) Parts name Model name External connect kit UTY-XWZXZ5 Communication kit UTY-TWBXF * For operating the EXTERNAL function, the wall mounted type requires the communication kit in addition to the wire (UTY-XWZXZ5).
11-2. EXTERNAL OUTPUT OPERATION STATUS OUTPUT An air conditioner operation status signal can be output. Circuit diagram example Indoor unit control PC board Communication kit Connected unit Connector 24V DC Ex.)Relay unit Ex.)Display Relay power supply *10 m Signal Optional parts Field supply...
Page 30
ERROR STATUS OUTPUT An air conditioner error status signal can be output. Circuit diagram example Indoor unit control PC board Communication kit Connected unit Connector 24V DC Ex.)Relay unit Ex.)Display Relay power supply *10 m Signal Optional parts Field supply * Make the distance from the PC board to the connected unit within 10m.
FUNCTION SETTINGS 12-1. INDOOR UNIT (Setting by remote controller) • The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings can cause the indoor unit to malfunction. •...
Page 32
FUNCTION DETAILS Wall Functions mounted 1) Filter sign 2) Cooler room temperature correction 3) Heater room temperature correction 4) Auto restart Indoor room temperature sensor switching function 6) Remote controller signal code 7) External input control 8) Indoor unit fan control for energy saving 1) Filter sign The indoor unit has a sign to inform the user that it is time to clean the filter.
Page 33
4) Auto restart Enable or disable automatic system restart after a power outage. ( ... Factory setting) Setting description Function number Setting value * Auto restart is an emergency function such as for power failure etc. Do not start and stop the indoor unit by this function in normal operation. Be sure to operate by the control unit, or external input device.
Page 34
REMOTE CONTROLLER SIGNAL CODE SETTING Use the following steps to select the signal code of the remote controller. (Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code.) Press the START/STOP ( / ) button until only the clock is displayed on the remote controller display.
OPTIONAL PARTS 13-1. CONTROLLER Exterior Parts name Model No. Summary Unit control is performed by Wired remote wired remote controller. UTY-RVNM controller *Optional communication kit is necessary for the installation. Unit control is performed by Wired remote wired remote controller. UTY-RNNM *Optional communication kit is controller...
Page 36
2. OUTDOOR UNIT SINGLE TYPE : AOG07LUCA AOG09LUCB AOG12LUC AOG14LUC DTR_AO126E_01 2012.11.26...
SPECIFICATIONS Type INVERTER COOLING & HEATING Model name AOG07LUCA AOG09LUCB AOG12LUC AOG14LUC Power source 230V~ 50Hz Available voltage range 198-264V ~ 50Hz Starting current Cooling 1,720 1,720 1,940 1,940 Airflow rate Heating 1,510 1,510 1,700 1,700 Type × Q'ty Propeller fan×1 Motor output Cooling Sound pressure level...
DIMENSIONS MODEL : AOG07LUCA, AOG09LUCB (Unit : mm) Top view Front view Side view Air flow Bottom view INSTALLATION PLACE When there are obstacles at When there are obstacles at When there are obstacles at the the back or front sides.
Page 40
MODEL : AOG12LUC, AOG14LUC (Unit : mm) Top view Front view Side view Air flow Drain pipe 4-ø11.3mm hole mounting place (ø20) Bottom view INSTALLATION PLACE When there are obstacles at When there are obstacles at When there are obstacles at the the back or front sides.
ADDITIONAL CHARGE CALCULATION MODEL : AOG07LUCA Refrigerant type R410A Refrigerant amount Refrigerant charge Total pipe length 15 or less 20 (MAX) 20g/m Additional charge MODEL : AOG09LUCB Refrigerant type R410A Refrigerant amount Refrigerant charge Total pipe length 15 or less 20 (MAX)
AIR FLOW MODEL : AOG07LUCA Cooling Number of rotations Air flow (r.p.m.) 1720 1012 Heating Number of rotations Air flow (r.p.m.) 1510 MODEL : AOG09LUCB Cooling Number of rotations Air flow (r.p.m.) 1720 1012 Heating ...
Page 49
MODEL : AOG12LUC Cooling Number of rotations Air flow (r.p.m.) 1940 1141 Heating Number of rotations Air flow (r.p.m.) 1700 1000 MODEL : AOG14LUC Cooling Number of rotations Air flow (r.p.m.) 1940 1141 Heating ...
ELECTRIC CHARACTERISTICS Model name AO G07LUCA AO G09LUCB AO G12LUC AO G14LUC Voltage 230 ~ Power supply Frequency *1) Max operating current 10.5 Starting Current Main Fuse (Circuit breaker) Current *2) Wiring Spec. Power Cable *3) Limited wiring length *1) The maximum current is the total current of indoor unit and outdoor unit.
SAFETY DEVICES Model Protection form AO G07LUCA AO G09LUCB AO G12LUC AO G14LUC Current fuse 250V 20A Circuit protection (Main printed circuit board) 250V 5A OFF: 100 ± 15°C OFF: 150 ± 15°C Fan motor protection Thermal protection program ON: 95 ±...