Chapter 2 Hardware Installation and Connection
Figure 5
Do NOT block the ventilation holes. Leave space between devices when
stacking.

2.3 Mounting the Switch on a Rack

The Switch can be mounted on an EIA standard size, 19-inch rack or in a wiring closet with
other equipment. Follow the steps below to mount your Switch on a standard EIA rack using a
rack-mounting kit.

2.3.1 Rack-mounted Installation Requirements

• Two mounting brackets.
• Eight M3 flat head screws and a #2 Philips screwdriver.
• Four M5 flat head screws and a #2 Philips screwdriver.
Failure to use the proper screws may damage the unit.
2.3.1.1 Precautions
• Make sure the rack will safely support the combined weight of all the equipment it
contains.
• Make sure the position of the Switch does not make the rack unstable or top-heavy. Take
all necessary precautions to anchor the rack securely before installing the unit.

2.3.2 Attaching the Mounting Brackets to the Switch

1 Position a mounting bracket on one side of the Switch, lining up the four screw holes on
the bracket with the screw holes on the side of the Switch.
38
Attaching Rubber Feet
GS-3012/GS-3012F User's Guide