York International ZK Series Installation Manual page 4

R-410a, 3 - 5 ton, 60 hertz
Table of Contents

Advertisement

5121817-TIM-A-0515
Nomenclature
Product Category
Z = A/C, Single Pkg., R-410A
T03 = 3.0 Ton
T04 = 4.0 Ton
T05 = 5.0 Ton
00 = Cooling Only. Suitable for Field
05 = 50 MBH Input (T03) Single Stage Only
07 = 75 MBH Input (T04) Single and Two Stage
07 = 75 MBH Input (T03 &T05) Two Stage Only
11 = 100 MBH Input (T03 &T05)
13 = 115 MBH Input (T03) Two Stage Only
13 = 125 MBH Input (T04 &T05) Single & Two Stage
05 = 5 KW
07 = 7 KW
10 = 10 KW
15 = 15 KW
20 = 20 KW
30 = 30 KW
A = Direct Drive
B = Direct Drive/Single Input Low Leak Econo
D = Direct Drive/Motorized Damper
N = Belt Drive
P = Belt Drive/Single Input Low Leak Econo
R = Belt Drive/Motorized Damper
T = Belt Drive High Static
U = Belt Drive High Static/Single Input Low Leak Economizer
V = Belt Drive High Static/Motorized Damper
4
Z K T04 N 07 A 2 A A 1 1 B A 4
Product Identifier
K = 13.0 SEER Reheat
Nominal Cooling Capacity
Heat Type
C = Cooling Only, No Heat Installed
E = Electric Heat
N = Alum Steel, Single Stage
S = Stainless Steel Single Stage
D = Alum Steel, Two Stage
T = Stainless Steel Two Stage
Heat Type and Nominal Heat Capacity
Installed Electric Heat
Gas Heat Options
Electric Heat Options
Airflow
1 = 208/230-1-60
2 = 208/230-3-60
3 = 460-3-60
4 = 575-3-60
Configuration Options
1 = Bottom Drain Composite
3 = SS Drain Pan
Filter Options
1 = 2" Throwaway Filters
2 = 2" Pleated Filters (Merv 7)
3 = 2" Cleanable Filters
4 = 4" Pleated Filters (Merv 13)
A = None
C = BACnet MSTP,Modbus,N2 COM Card
F = FDD
H = Hnywll Excel 10 Ctrl, DFS, APS
N = Novar UCM Ctrl, DFS, APS
P = CPC Control, DFS, APS
R = Commercial Control System (CCS) Single Zone
S = Commercial Control System (CCS) Change over bypass
Installation Options
A = No Options Installed
B = Option 1
C = Option 2
D = Options 1 & 2
E = Option 3
F = Option 4
G = Options 1 & 3
H = Options 1 & 4
J = Options 1, 2 & 3
K = Options 1, 2, & 4
L = Options 1,3 & 4
M = Options 1, 2, 3, & 4
Voltage
N = Options 2 & 3
P = Options 2 & 4
Q = Options 2, 3, & 4
R = Options 3 & 4
S = Option 5
T = Options 1 & 5
U = Options 1, 3, & 5
V = Options 1, 4, & 5
W = Options 1, 3, 4, & 5
X = Options 3 & 5
Y = Options 4 & 5
Z = Options 3, 4 & 5
Options
1 = Disconnect
2 = Non-Pwr'd Conv. Outlet
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet
Product Generation
4 = Fourth Generation
Coated Coils
A = Un-Coated
B = E-Coat Cond & Evap Coils
C = E-Coat Condenser Coil
D = E-Coat Evaporator Coil
Additional Options
A=No Options
B= Phase Monitor (PM)
C = Coil Guard (CG)
D = Dirty Filter Switch (DFS)
E = PM & CG
F = PM & DFS
G = CG & DFS
H = PM, CG, & DFS
Control Options
Johnson Controls Unitary Products