Technical Data; Pressure Gauge - ICI Caldaie ECOVAPOR Series Instructions For Installation, Use And Maintenance Manual

Steam generating unit with integrated burner
Table of Contents

Advertisement

TECHNICAL DATA

DESCRIPTION
Useful nominal power
[1]
Nominal thermal flow
Minimum nominal power
Minimum thermal flow
Efficiency at 100% (ref. P.C.I.)
[1]
Furnace depression (Flue gas pressure drop)
Rated pressure
Total capacity
Capacity at level
EXCHANGE surface
Steam production
[1]
Rated frequency ~ voltage
Electric protection rating
Absorbed power
Allowed fuels
Lower calorific value
Max. / min. fuel pressure values
Fuel nominal flow rate (G max gas flow rate)
Minimum fuel flow rate
Flue gas temperature at nominal power
Total weight
[1]
80 °C treated water feed temperature.
SAFETY COMPONENT CALIBRATIONS
The components listed below are adjusted at the indicated pressure values
– safety valve: 12 bar (factory sealed - do not modify)
– safety pressure switch: 11 bar (factory sealed - do not modify)
– pressure transducer: 10 bar (adjust during installation, if necessary).
COMPONENTS
The steam generating systems
– Safety components (safety valves, safety level switches, safety pressure switch).
– Indicators (level indicator, manometer, flame light).
– Adjustment components (level adjusters, pressure switches, pressure transducers).
– Feed components (centrifugal pump).
– Operation components (shut-off valves, drain valve).
Hereinafter are the descriptions of the operation of each single component.

PRESSURE GAUGE

The manometer indicates the reached steam pressure value. The value of the design pressure is shown in red on the graduated
scale.
The manometer is fitted onto a three-way valve allowing to carry out the following operations:
– Communication between generator and pressure gauge (normal operating position).
– Communication between pressure gauge and the outside (position needed to purge the siphon).
– Communication between generator, pressure gauge and sample pressure gauge (position needed for pressure gauge
comparison).
General information
u.m.
350
kW
238
kW
254
kW
30
kW
31
%
mbar
n.a.
bar
l
921
l
673
m
2
8,30
kg/h
350
Volt /Hz
IP
kW
MJ/m
3
mbar
Stm
3
/h
26,85
Stm
/h
3
3
°C
135
kg (12 bar
2180
version)
ECOVAPOR
feature a series of components that can be divided into:
ECOVAPOR
500
650
800
1000
341
443
545
681
362
471
580
725
43
55
68
85
44
58
71
89
-32
1250
1830
950
1280
12,80
14,20
500
650
800
1000
6
7
Natural gas
34,2
17,25
38,35
49,86
61,37
76,71
4
5
6
8
135
135
135
135
2180
2550
2550
3240
1350
1700
2000
920
1158
1363
979
1232
1450
115
145
170
120
151
177
94
n.a.
12-15
2190
2640
3050
1475
2000
2300
22,30
25,00
31,5
1350
1700
2000
400/50
IP55
9
14,5
15,5
103,56
130,40
153,42
10
135
135
135
3690
4400
5250
2500
3000
1703
2044
1812
2175
213
256
222
266
3380
4020
2490
2825
40,5
48
2500
3000
19,5
191,77
230,12
135
135
5920
6320
15