Installation Lock Cover; Installation Half Cylinder; Mounting Alarm Signalling Device - Honeywell Tagalarm-Plus Mounting And Operating Instructions

Doorguard for mb panels bus-2
Table of Contents

Advertisement

Available languages

Available languages

36
4.2.4

Installation lock cover

The scope of delivery includes a lock cover that is used when the Doorguard is to be operated exclusively through
ID data carriers and no profiled half-cylinder is required.
Disengage the retaining clip (see diagram below) from the operating switch.
N
Lock in the lock cover into the upper part of the housing from the front side.
O
Locked cover.
P
In case the subsequent assembly of a profile cylinder is excluded, agglutinate the lock cover on the inside of
Q
the upper part of the housing according illustration to increase the manipulation safety. Therefore use a
commercially available instant gel adhesive, i. e. LOCTITE 454 or UHU SEKUNDENKLEBER instant
SUPERGEL (48790).
4.2.5

Installation half cylinder

The half cylinder is not included in the scope of delivery.
Due to the constructional differences of half cylinders produced by
various manufacturers, the locking cylinder must be carefully selected.
The length A (see drawing) should be 30 mm. The housing cover is
designed for the length A = 30 mm (optional max. 35 mm). We
recommend the use of the half cylinder Item no. 028032.
- The retaining clip must be put on the operating switch (see
diagram). The retaining clip protects the switching flag against
damage when mounting the half cylinder.
- Turn the assembly screw (M5 x 16) from the right approx. 10 mm
into the selected half cylinder.
- Turn the "lock lug" 90° clockwise into the normal position (release
position)
- Insert the half cylinder into the cylinder mount of the housing base and
screw down. If necessary attach returning spring to the "lock lug".
- Insert the key in the half cylinder
- Remove the retaining clip on the operating switch
- Test the operating function by turning (key-operated switch) clock wise to the limit.
On releasing the key, the return spring should press the "lock lug" into the normal position. If necessary,
readjust the half cylinder using the assembly screw.
4.3

Mounting Alarm signalling device

Attach the housing on the 2 fixing holes on a firm mounting
substrate. To fix securely, use screws that are suitable for the
mounting surface in question. Depending on the mounting substrate,
with or without dowel.
Tighten the screws finger-tight.
Screw the tear-off protection directly to the mounting surface using
the enclosed screw and spacer sleeve. Dowels may be necessary,
depending on the mounting surface.
Mounting and Operating Instructions Doorguard for MB panels BUS-2