Permanent Release With Automatic Activation - Honeywell Tagalarm-Plus Mounting And Operating Instructions

Doorguard for mb panels bus-2
Table of Contents

Advertisement

Available languages

Available languages

Mounting and Operating Instructions Doorguard for MB panels BUS-2
10.5.3

Permanent release with automatic activation

When deactivated, a further operation for longer than 3 seconds can activate permanent release
(regardless of programming).
The door then has to be opened during the door release time.
The door can then remain open for any length of time without any reminder signal.
Activation is performed automatically the first time the door is closed.
Operating
9 Sequence 9
or
or
13
Required software: MB24/48/100 from V18.xx, MB-Secure fromV04.xx (see 1.2.2)
Duration
Operating state
Doorguard active
> 200 ms
Doorguard inactive
> 3 seconds
Permanent release
Operation during
Open the door within
door lock release
the door opening time
Permanent release
permanent door
release permitted,
irrespective of
parameterization
Doorguard active
when the door is
13
Red LED
"Activation"
Off
Off
Lights up (static)
when door is
opened
Off
closed
45
Green LED
"Operating state"
Lights up (static)
Lights up (static)