Technical Data - Honeywell Tagalarm-Plus Mounting And Operating Instructions

Doorguard for mb panels bus-2
Table of Contents

Advertisement

Available languages

Available languages

Mounting and Operating Instructions Doorguard for MB panels BUS-2
9.

Technical data

Operating unit
Operating voltage U_b
Operating voltage range
Current consumption
Detector group voltage
Detector group end-of-line resistor
Monitoring range
Output for acoustical alarm signalling
Output for optical alarm signalling
Transponder reader
Frequency range, Transmission power
Half cylinder as per DIN 18252
Operating temperature range
Storage temperature range
Environmental class as per VdS
Protection class as per EN 60529
Dimensions (W x H x D)
Colour
Alarm signalling device
Operating voltage range
Current consumption - acoustical alarm
Current consumption - optical alarm
Acoustical alarm signalling
Optical alarm signalling
Operating temperature range
Storage temperature range
Environmental class as per VdS
Protection class as per EN 60529
Dimensions (W x H x D)
Housing colour
Hereby, the Novar GmbH declares that the radio equipment Doorguard for MB panels BUS-2, Item no.
041450.17 is in compliance with Directive 2014/53/EU.
The full text of the EU declaration can be downloaded from our homepage https://www.security.honeywell.de/ in the
service/download area.
12 V DC
10 V DC to 15 V DC
< 15 mA (average)
8 V DC
12K1 or 10k (programmable, MB-Secure 4k to 14k6)
±20%, ±30% or ±40% (programmable)
 40 mA (active low)
 40 mA (active low)
for IK2/proX1 and IK3/proX2 data carriers
125 kHz, <10 dBµA/m
Standard dimension A = 30 mm, A = 35 mm possible
-5 °C to +45 °C
-25 ° C to +70 ° C
II
IP 40
110 x 140 x 53 mm
traffic white (similar to RAL 9016)
9 V DC to 15 V DC
Programming interval tone # 25 mA
Programming continuous tone # 50 mA
# 25 mA
Loudness level approx.100 dBA
LED - flash interval approx. 1.5Hz
-5 °C to +45 °C
-25 ° C to +70 ° C
II
IP 40
110 x 103 x 53 mm
traffic white (similar to RAL 9016)