Alarm signalling device

AVOID INJURY TO EYES!
The device is equipped with LEDs Class 1M
(EN 60825-1).
Do not look directly into the light beam of the flashing
LEDs - danger to eyes. Do not use tightly converging
instruments (lenses) for observing the light beam. Only
use the alarm signalling device together with the
housing cover (glare and diffusor protection).
4.

Mounting

4.1

Installation versions

The housing of the Doorguard for MB panels BUS-2 comprises an operating and alarm signalling device. They can
be installed together or separately (e.g. operating unit next to the door, alarm signalling device above the door). To
open the housing cover, loosen the housing screws at the top and bottom.
The enclosed junction must be inserted between
both housing bases to ensure the correct distance
between both housings.
In the case of remote installation, a cable duct can
be used to connect both housing sections.
A connection line must be laid between the
operating unit and the alarm device and connected
accordingly. Four wires are required for alarm
signalling and two further wires for tamper
monitoring (see connection diagram).