Download Print this page
TDK-Lambda DRB120 Series Instruction Manual
TDK-Lambda DRB120 Series Instruction Manual

TDK-Lambda DRB120 Series Instruction Manual

Advertisement

Quick Links

PA620-04-xxx
PA634-04-02
DRB120 Series Instruction Manual
BEFORE USING THE POWER SUPPLY UNIT
Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock,
damage to the unit or a fire hazard.
• Warning Symbols
.
DO NOT MODIFY OR DISASSEMBLE THE POWER SUPPLY.
.
READ INSTRUCTION MANUAL BEFORE CONNECTING TO MAINS.
.
ELECTRIC SHOCK HAZARDOUS ON THE CONNECTOR SECTION.
NOTICE:
(1) Installing/Storage Environment
1. Store the product with ambient temperature –40 to +85 °C, and relative humidity 5 to 95% (No dewdrop).
2. Avoid operating the unit in over current, short circuit or out of input voltage range which could result in damage.
3. Confirm connections to input/output terminals are correct as indicated in the instruction manual.
4. Use the product where the relative humidity is 5 to 95% (No dewdrop).
5. Avoid places where the product is subjected to direct sun light.
6. Avoid places where the product is subjected to penetration of liquid, foreign substance or corrosive gas.
7. Avoid places subject to shock or vibration.
A device such as a contact breaker may be a vibration source. Set the power supply as far as
possible from any source of shock or vibration.
8. If the Power Supply is used in an area with excessive electronic noise, be sure to separate the
Power Supply as far as possible from the noise sources.
9. Don't use the product in the environment with strong electromagnetic field, corrosive gas and conductive
substance.
10. Model/type reference: DRB120-24-1-xyz (where xyz is optional and can be alphanumeric
characters or blank and it is not a safety related information - product ratings unchanged)
Precautions in Using the product:
When the product is used under the circumstance or environment below, ensure adherence to limitations of
the ratings and functions.
Also take countermeasures for safety precautions such as fail-safe installations.
1. Under the circumstances or environment which are not described in the instruction manual.
2. For nuclear power control, railway, aircraft, vehicle, incinerator, medical equipment, entertainment
equipment, safety device etc.
3. For applications where death or serious property damage is possible and extensive safety precautions are required.
4. Not to be used with a high inductive power source as it may cause unstable operation of the power supply.
Note: CE MARKING
CE Marking, when applied to a product covered by this handbook indicates compliance with the following:
Low Voltage Directive in that it is complies with EN60950-1.
EMC Directive
Restriction of the use of certain Hazardous Substances Directive
For further installation instructions refer to web link:
emea.tdk-lambda.com/PA634-04-01_
CAUTION
TDK-Lambda
DRB120 Series
INSTRUCTION MANUAL

Advertisement

loading
Need help?

Need help?

Do you have a question about the DRB120 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TDK-Lambda DRB120 Series

  • Page 1 PA634-04-02 DRB120 Series INSTRUCTION MANUAL DRB120 Series Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
  • Page 2 TDK-Lambda PA634-04-02 DRB120 Series INSTRUCTION MANUAL +V: +Output terminal 2. Terminal Explanation - V: - Output terminal 2-1. DRB120 V.ADJ: Output voltage adjust trimmer The output voltage rises when trimmer is turned clockwise. L: AC Input terminal Live line (fuse in line)
  • Page 3 TDK-Lambda PA634-04-02 DRB120 Series INSTRUCTION MANUAL 4. Explanation of Functions and Precautions Load 4-1. Input Voltage Range 1.5m 50Ω Cable Input voltage range is single phase 85 ~ 264VAC (47~63Hz) P.S. C1 C2 can withstand 300VAC surge for 5 seconds during operation.
  • Page 4: Withstand Voltage

    TDK-Lambda PA634-04-02 DRB120 Series INSTRUCTION MANUAL 4-8. Isolation Test Input ~ Output (dotted line ) Isolation resistance between output and (Protective Earth) 4243VDC 1min. ( 20mA ) shall be more than 100MΩ at 500VDC. For safety operation, Input ~ (Protective Earth) (solid line) voltage setting of DC isolation tester must be done before 2500VDC 1min.
  • Page 5: Mounting Directions

    TDK-Lambda PA634-04-02 DRB120 Series INSTRUCTION MANUAL 6. Mounting Directions 6.1. Power supply mounting on DIN RAIL (TS35 or equivalent) Recommended standard mounting method is vertical with the output connector uppermost. Do not exceed the load Make sure input and output wire disconnected when deratings.
  • Page 6 DRB120 Series INSTRUCTION MANUAL (3) Press against the bottom front side for locking. 7. Output Derating – DRB120 series Shake the unit slightly to check the locking action. (4) In order to tighten the unit mounting, the Din rail stopper attached on both sides of the unit is recom- mended.
  • Page 7 TDK-Lambda PA634-04-02 DRB120 Series INSTRUCTION MANUAL 10. DRB120 series UL508 Listed Condition WIRING CONNECTOR Recommended Wire Rated Torque INPUT 10.3 kgf.cm 10~24 AWG (L, N, (9 lbf.in) OUTPUT 10.3 kgf.cm 10~24 AWG (+V, -V) (9 lbf.in) OUTPUT 10.3 kgf.cm 10~24 AWG (DC OK) (9 lbf.in)

This manual is also suitable for:

Drb120-24-1