To rapidly assess the condition of your batteries, measure monthly the density of each cell using a
hydrometer, as a function of the temperature, using the graphs below (do not measure immediately after
filling).
1.30
1.29
- 70
1.28
- 67
1.27
- 62
1.26
- 58
1.25
- 49
1.24
- 42
1.23
-40
1.22
-31
1.21
-27
1.20
-25
1.19
-23
1.18
-20
1.17
-16
1.16
-14
1.15
-12
1.14
-11
1.13
-10
1.12
-8
1.11
1.10
100 %
Figure 1 : Charging state of a battery as a function of density and temperature.
Do not electric arc weld on the machine without first disconnecting the batteries.
4.9.

MANUAL EXTENSIONS.

See photo 9.
The platforms are fitted with one manual extension as
standard. The second extension is optional.
Conditions of use
• To extend or retract the extension, take the two
handles provided, lift them up to 90° and push them in
the desired direction. Lifting the handles by 90°
automatically releases the retaining bolts (1) into the
extension position.
• During transit on a trailer or vehicle, and during use,
the manual extensions must be locked: check that the
bolts are well engaged when the handles return to
their initial position, to prevent inadvertent in/out
movement of the extension.
DO NOT RECHARGE
80 %
ELECTROLYTE FREEZING POINT IN °C
FOR DENSITIES UNCREASED TO 30°C.
Never use the batteries to start another machine.
RECHARGE
60 %
40 %
WARNING.
Photo 9 : Manual extension handle.
34
STOP !
RECHARGE
NOW
15°C
30°C
45°C
20 %
0 %
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H12 sdxH12 sdeH15 sdH15 sdxH15 sdeH18 sdx

Table of Contents