Amprobe 5XP-A User Manual page 23

Compact digital multimeter
Hide thumbs Also See for 5XP-A:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 3
AC CURRENT (45 Hz to 500 Hz)
Ranges: 400 µA, 4000 µA, 40 mA, 400 mA, 2A
Accuracy: ± (1.5 % rdg + 5 dgts) on 400 µA to 400 mA ranges:
± (2.5 % rdg + 5 dgts) on 2 A range
RESISTANCE
Ranges: 400 , 4 k, 40 k, 400 k, 4 M, 40 M
Accuracy: ± (1.0 % rdg + 4 dgts) on 400 to 4 M
ranges: ± (3.0 % rdg + 5 dgts) on 40 M range
CONTINUITY
Audible indication: Less than 25 
DIODE TEST
Test current: 1.2 mA (approximate)
Accuracy: ±(1.5 % rdg + 3 dgts)
Open circuit volts: 3.0 dc typical
CAPACITANCE
Ranges: 4 nF, 40 nF, 400 nF, 4 µF, 40 µF, 400 µF, 4 mF
Accuracy: ± (5.0 % rdg + 30 dgts) on 4 nF range: ± (5.0 % rdg
+ 5 dgts) on 40 nF and 400 µF ranges: ± (5.0 % rdg + 15 dgts)
on 4 mF range
TEMPERATURE
Ranges: -20°C to 1000°C, -4°F to 1832°F
Accuracy: ± (2.0 % rdg +4°C) -20°C to 10°C
± (1.0 % rdg + 3°C)10°C to 200°C
± (3.0 % rdg + 2°C) 200°C to 1000°C
± (2.0 % rdg + 8°F) -4°F to 50°F
± (1.0 % rdg + 6°F) 50°F to 400°F
± (3.0 % rdg + 4°F) 400°F to1832°F
FREQUENCY
Ranges: 4 k, 40 k, 400 k, 1 MHz
Accuracy: ± (0.1 % rdg + 3 dgts)
Sensitivity:10 Hz to 1 MHz: >2.5 V rms
OVERLOAD PROTECTION
Voltage, Resistance, Diode, Continuity, Frequency,
17
GlobalTestSupply
www.
.com
Find Quality Products Online at:
sales@GlobalTestSupply.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

15xp-b35xp-a

Table of Contents