The SNMP zone
The product supports SNMP versions V1, V2c and V3. The SNMP protocol can operate in one of the following
modes:
Read/Write
The data can be viewed and modified via the SNMP protocol. Actions can be implemented.
Read Only
The data can only be viewed via the SNMP protocol.
Version SNMP V1 and V2c: Click on "OK" next to "SNMP" to save the configuration.
Version SNMP V3 :
User USM
Create a login.
Auth Algorithm
Choose the algorithm to hash the password corresponding to the login.
Auth Password
Enter a password of between 8 and 16 characters.
Privacy Algorithm
Choose the encryption algorithm.
Privacy Password
Enter an encryption code of between 8 and 16 characters.
Click on "OK" next to "Privacy Password " to save the configuration.
If the user wishes to receive SNMP traps, he/she must configure the IP address of the SNMP servers receiving
them. To save the changes, click on "OK" to the right of the same row.
If the function is to be disabled, enter the IP address of "0.0.0.0".
Two SNMP servers can be entered.
The rack language zone
The language of the rack display is independent of the website language. Remote maintenance can be carried
out without difficulty by a person who understands one of the 6 available languages.
To change it, simply display the pop-up menu by clicking the bottom arrow
then click on the "Change" button.
The Load the MIB zone
For ease of maintenance, the MIB is available as a simple link on the site. Simply click the link to download the
RMS- MIB.zip file that contains the MIB associated with SNMP traps.SNMP operation (sending fault traps)
The User group
The user group is only used to change your password and view the connection settings.