INDEX Displaying the temperature detected by the separate probe ..........15 Introduction ..............3 Statistical data ..........15 Controls and indications ..........4 Setting the desired humidity level ....16 Controls .............4 Maintenance ............17 Indications ............5 Replacing the batteries ........17 User manual ............6 Installation .............18 Setting the date and time ........6 Installing the batteries ........18 Summer/Winter selection ........7...
Introduction • Telephone actuator with GSM modem, used for remote control by means of SMS mes- sages. The CH150RF/151RF/152RF programmable thermostat measures the ambient temperature Both telephone actuators allow you to: and controls the heating (conditioning) system • remotely interrogate the programmable ther- through a radio connection with an actuator.
Controls and indications 7. Rotary selector for temperature correction: T1, Manual temperature, Jolly temperature, Controls Antifreeze temperature * 8. Rotary selector for correcting temperature T2 or the Jolly operating mode duration * 9. Rotary selector for correcting temperature T3 or the Jolly operating mode duration 10.
Indications 1. Time 2. Temperature profi le 3. Temperature value T1 or “Jolly” operating mode duration (days) 4. Temperature value T2 or “Jolly” operating mode duration (hours) 5. Temperature value T3 6. System ON in Summer operation 7. System ON in Winter operation 13 12 8.
User manual 2. Modify the hour setting by means of the ▲ and ▼ buttons, then go to the minute setting by means of the ► button. To operate the programmable thermostat after it has been installed, proceed as follows: 1.
5. Press ENTER again to exit the program- Operating modes ming menu. The programmable thermostat The CH150/151/152 programmable thermo- operating mode previously interrupted will be stat features four different operating modes: resumed. Manual, Automatic, Holiday and Jolly (in addi- tion to the OFF function). “Manual”...
The temperature level can be modifi ed during “Automatic” operating mode operation by means of the lower rotary selector With the “Automatic” operating mode, the pro- located on the right side of the programmable grammable thermostat adjusts the operation thermostat. The temperature can be changed of the heating or cooling system by following from 2°C to 40 °C by 0.1°C increments.
Page 9
Temperature T3 cannot be lower than tem- Temperature T1 cannot be higher than tem- perature T2 or higher than 40 °C. perature T2 or lower than 2 °C. During Summer operation, temperature T3 features an upper limit of 30°C. When this value is exceeded, T3 will take the OFF value, which will involve switching the system off.
“Holiday” operating mode “Jolly” operating mode With the “Holiday” operating mode, the CH150 “Jolly” operating mode programmable thermostat CH150 adjusts the With the “Jolly” operating mode, the CH150 operation of the heating or cooling system by programmable thermostat interrupts the cur- following one single temperature profi...
Page 11
Use the lower rotary selector to modify the To set the “Jolly” operating mode duration, i.e. temperature level. days («d»), use the upper rotary selector. The The temperature can be modifi ed from 2°C to days can range from 0 to 99. 40 °C, by 0.1 °C increments.
“OFF” function The “OFF” function can be activated by press- ing OFF. Winter operation Summer operation The programmable thermostat adjusts the op- eration of the heating system to keep the “An- tifreeze” temperature, in order to reduce the energy consumption and, at the same time, avoid any damage caused by extremely low temperatures.
Preset programs Programmable thermostat programming The CH150 programmable thermostat fea- You can customize the temperature profi les for tures two preset programs (i.e. “Winter” and the “Automatic” and “Holiday” operating modes, “Summer”) for quicker start-up. so as to adapt them to your own needs. To set new temperature profi...
Page 14
2. The Monday profi le (DAY 1) for “Winter” op- 4. To directly duplicate the temperature pro- eration (icon ) will be displayed. Use the fi le by going to the next day, press COPY (to ◄ and ► buttons to move the bar chart blink- customize every single day separately, refer to ing segment to the time at which the tempera- step 5 below).
Preset parameter reset Statistical data To resume the preset temperature profi les and The CH150 programmable thermostat provides values (T1-T2-T3-Temperature used with the a set of statistical data concerning the system Manual mode, Temperature used with the Jolly operation. To access this data, proceed as fol- mode, Antifreeze temperature, OFF function), lows: keep the ▲...
3. Page 2: total number Setting the desired humidity level of hours during which The CH150RF/151RF/152RF programmable the system has been thermostat allows you to actuate a humidistat switched on and operat- by setting the desired humidity value. To be ing since its fi...
2. Use the ► button to move and highlight the Maintenance set humidity value. The programmable thermostat can be cleaned by using a soft cotton cloth (no detergent must be used). Replacing the batteries When the battery charge level starts to read low, symbol will start blinking on the dis- play.
Installing the batteries Important! The standard battery service life is more than 1 year. It is recommended that Separate the socket from the programmable thermostat by levering on the slot found at the the batteries should be replaced at the start of the system operation season, to prevent the socket bottom by using a suitable tool.
Page 19
Parameter Writing Values Preset value Type of con- rEL/ rAd / --- None nected card Heating actuator rF t -- - registration radio control Each confi guration parameter, which features Humidity adjust- ON/OFF its own preset settings, is identifi ed on the dis- ment enable play by an index and a writing.
Page 20
Type of connected card Parameter Writing Values Preset The programmable thermostat is capable of value verifying whether the socked is connected. If Ambient tem- Corr -4.0 °C to 0.0 °C perature +4.0 °C the socket is not connected, the dashes will be correction displayed;...
Page 21
for more information. This menu item will be Adjustment band displayed only if the humidity adjustment has It sets the adjustment band when the propor- been enabled. tional temperature adjustment mode is chosen. Select an appropriate value on the basis of the Temperature scale system’s temperature gradient (wide band for It selects the scale, i.e.
Page 22
• Floor probe (FLO): when the temperature when the fl oor probe is used (for the fl oor heat- detected by the probe reaches the value set ing systems). in the Floor temperature limit parameter, the system will be switched off regardless of the Ambient temperature correction temperature detected by the programmable It makes it possible to sum/subtract an offset...
turned on during the day. correctly connected with the programmable thermostat (refer to Index 1 of the confi guration menu, <<Programmable thermostat confi gura- Software revision and radio address tion>> chapter). It displays the software revision for the unit in Heating system actuator registration: which the ambient temperature is usually in- 1.
Page 24
2E. Press ENTER [button 5] to go back to the (it must be set to “ON”); otherwise, use the ▲ initial page of the programming menu; press [button 1] and ▼ [button 2] buttons to enable the same button again to go back to the oper- the same.
send a radio control every minute. During the Separate the socket from the programmable normal operation, some radio signals might be thermostat by levering on the slot found at the lost due to external disturbance: in any case, socket bottom by using a suitable tool. such disturbance will, provided it does not of- ten occur in time, not affect the correct equip- Make sure that the socket is properly secured...
Electric connections Connecting the telephone actuator Prior to making the connections, remove the Connect the three telephone actuator wires terminal protection guard (the latter shall with screw clamps 1, 2 and 3, as illustrated in be kept together with the fastening crossed the fi...
CTx TERMINAL BLOCK 1 2 3 SEPARATE CH150 TERMINAL TEMPERATURE BLOCK PROBE Securing the programmable thermostat to the socket Manually press the programmable thermostat to fi t the same to the socket, making sure that the multi-pole connector is correctly inserted. The programmable thermostat clicks into posi- tion.
Technical features Power supply 2 AA alkaline batteries Local controls 7 buttons 3 rotary selectors (1.5 V) Dimensions (L x H x D) 155 x 91 x 20 Battery life More than 1 year Separate temperature probe 10 m max Inputs Telephone actuator distance...
Page 29
Fantini Cosmi S.p.A. reserve the right to make any necessary technical and construction modifi cations without giving advance notice.
Page 31
DISPOSAL OF PRODUCTS The crossed out wheeled dust bin symbol indicates that products must be collected and disposed of separately from household waste. Integrated batteries and accumulators can be disposed of with the product. They will be separated at the recycling centres. The black bar indicates that the product was placed on the market after August 13, 2005.
Page 32
FANTINI COSMI S.p.A. Via dell’Osio, 6 20090 Caleppio di Settala, Milano - ITALY Tel. +39 02 956821 Fax +39 02 95307006 | info@fantinicosmi.it EXPORT DEPARTMENT Ph +39 02 95682229 export@fantinicosmi.it www.fantinicosmi.com...
Need help?
Do you have a question about the CH150RF Series and is the answer not in the manual?
Questions and answers