Download Print this page

Aqua Lung LPIS Technical Manual page 17

Low pressure inflation system / dry suit inflation system
Hide thumbs Also See for LPIS:

Advertisement

PART #
108312
108433 / 108337
108431 / 108341
054201
108318
108308
102810
TEST
Leak Test
MP
Swivel Relief Test
TABLE 5: RECOMMENDED CLEANERS AND LUBRICANTS
LUBRICANT/CLEANER
Christo-Lube MCG 111
Oakite #31
White distilled vinegar
Liquid dish washing detergent
(diluted with warm water)
TABLE 3: TORQUE SPECIFICATIONS
DESCRIPTION / KEY ITEM #
First Stage Body (32)
Screw, Relief Valve (17a)
Swivel Plug, w/ Relief (17d)
Safety Plug (11)
Bonnet (24)
Fill Port (36)
Pressure Gauge (38)
TABLE 4: TEST BENCH SPECIFICATIONS
CONDITION
Inlet 2,500-3,000 psi
Inlet 2,500-3,000 psi
170+/- 5 psi - 210+/- 5 psi
APPLICATION
All o-rings
CAUTION:
Silicone rubber requires no lubrication or preservative treatment. DO
NOT apply grease or spray to silicone rubber parts. Doing so may cause a chemical
breakdown and premature deterioration of the material.
Acid bath for reusable stainless steel and
brass parts.
CAUTION:
Do not use muriatic acid for the cleaning of any parts. Even if strongly
diluted, muriatic acid can harm chrome plating and may leave a residue that is
harmful to o-ring seals and other parts.
Acid bath for reusable stainless steel
and brass parts.
Degreaser for brass and stainless steel
parts; general cleaning solution for plastic
and rubber
TORQUE
25 ft-lbs (33.9 Nm)
45 in-lbs (5.1 Nm)
60 in-lbs (6.8 Nm)
90 in-lbs (10.2 Nm)
90 in-lbs (10.2 Nm)
90 in-lbs (10.2 Nm)
45 in-lbs (5.1 Nm)
SPECIFICATION
No leaks allowed
135±20 psi
170 +/- 5 psi for 30 seconds; no leak.
Pressure release can occur from 175
psi minimum and must release by 210
psi maximum to be accepted.
SOURCE
Aqua Lung, PN 820466, or
Lubrication Technologies
310 Morton Street
Jackson, OH 45640
(800) 477-8704
Oakite Products, Inc.
50 Valley Road
Berkeley Heights, NJ 07922
"Household" grade
"Household" grade
17

Advertisement

loading

This manual is also suitable for: