minutes after last touch (or pressing any button on the control panel).
Touchscreen Lock - The item allows you to lock the screen after last touch (or pressing any button on the
control panel). The time delay can be set in range of 1-10 minutes.To unlock the screen, press the
[ENTER/Display On] button.
Recalibrate Touchscreen - The item starts calibration of the touch screen. Follow the instructions on
the screen.
Display Orientation - The menu allows to change display orientation.
Normal - Standard display orientation if the fixture is placed horizontally (e.g. on the ground).
Inverted - Inverted orientation (needed if the fixture is hanging on the truss).
Auto - The option activates a gravitation sensor for automatic screen orientation.
Note: Auto option is set as default. You change the display orientation by touching the icon
an the option set in the "Display Orientation" menu is temporarily overriden.
Temperature unit - Use the menu item to change temperature unit from °C to °F.
Fan Mode - Use the menu to set the fixture fans to max. power mode ("High") or to the auto-control mode
("Auto"). The option "Quiet" allows you to set desired fan noise. The light output of the fixture
is reduced at low speeds of fans and the High-power Mode is deactivated.
High-power Mode - If the High-power Mode is On, the light output from the fixture will be increased about 6%
towards to the operation with fans in High mode. Fans will run on max. power.
Dimmer Curve - Use the menu to select desired dimmer curve: Linear or Square Law.
Date & Time Settings - Use this menu to set current date and time for the fixture log system (menu "View
Logs"). Set this menu items before first fixture operation.
Default Settings - The menu item allows to set all fixture parameters in this menu to the default (factory) values
except items "DMX Input".
Password Protection - allows to enter password in order to prevent unauthorized person from changing setting
of the fixture.
Reset Web Password - The menu item allows you to reset a password for access on the Web server (default
password: 2479, user: robe).
7.4 Tab "Manual Control"
Reset Functions - The menu allows to reset the fixture either per function modules or all modules together.
Total System Reset - The item resets all function modules.
Pan/Tilt Reset - The item resets a pan and a tilt.
Colour System Reset - The item resets colour wheel 1/colour wheel 2 and CMY+CTO system.
Gobo/Eff. Wh. Reset - The item resets static and rotating gobo wheel and an effect wheel.
Optics/Prism/Frost Res. - The item resets a zoom, focus, prism and a frost module.
Iris/Framing Sh. Reset - The item resets an iris module and framing shutters.
Manual Effect control - Use the menu to control all fixture channels by means of the control panel.
7.5 Tab "Stand-alone"
Test Sequences
-Use the menu to run a test/demo sequences without an external controller, which will show
you some possibilities of using Robin Esprite.
29
on the display,
Need help?
Do you have a question about the Robin Esprite and is the answer not in the manual?