Specifications; Pin Assignment - Sony RCP-3100 Operating Instructions Manual

Remote control panel
Table of Contents

Advertisement

Specifications

General
Power supply
10.5 V to 30 V DC (when using CCU/CNU
REMOTE connector, EXT I/O connector)
PoE (IEEE802.3af Class 2 compliant)
Power consumption
4 W
Operating
5 °C to 40 °C (41 °F to 104 °F)
temperature
Storage temperature
–20 °C to +55 °C (–4 °F to +131 °F)
Mass
1.4 kg (3 lb 1.4 oz)
External dimensions (Unit: mm (inches))
7
2- ∅5 (
/
)
32
1
80 (3
/
)
4
1
80 (3
/
)
4
Inputs/outputs
REMOTE
(NETWORK)
RJ-45 8-pin (1)
10BASE-T, 100BASE-TX, 1000BASE-T
8-pin multi-connector (1)
CCU/CNU
D-Sub 9-pin, female (1)
EXT I/O
Supplied accessories
Before Using This Unit (1)
Operating Instructions (CD-ROM) (1)
Switch assignment label (1)
Optional accessories
CCA-5-3 remote cable (3 m)
CCA-5-10 remote cable (10 m)
CCA-5-30 remote cable (30 m)
EXT I/O connector (JAE DE-9PF-N, 1-568-182-11)
Design and specifications are subject to change without
notice.
Note
Service mode of the unit is accessed using the following URL.
(http:192.168.1.1/service)
Repairs may be required if service mode settings are
changed.
Notes
• Always verify that the unit is operating properly before use.
SONY WILL NOT BE LIABLE FOR DAMAGES OF ANY
KIND INCLUDING, BUT NOT LIMITED TO,
COMPENSATION OR REIMBURSEMENT ON ACCOUNT
OF THE LOSS OF PRESENT OR PROSPECTIVE
PROFITS DUE TO FAILURE OF THIS UNIT, EITHER
DURING THE WARRANTY PERIOD OR AFTER
EXPIRATION OF THE WARRANTY, OR FOR ANY
OTHER REASON WHATSOEVER.
• SONY WILL NOT BE LIABLE FOR CLAIMS OF ANY KIND
125 (5)
MADE BY USERS OF THIS UNIT OR MADE BY THIRD
3
67 (2
/
)
4
PARTIES.
• SONY WILL NOT BE LIABLE FOR THE TERMINATION
OR DISCONTINUATION OF ANY SERVICES RELATED
TO THIS UNIT THAT MAY RESULT DUE TO
CIRCUMSTANCES OF ANY KIND.

Pin Assignment

EXT I/O connector (9-pin, female)
Pin
1
2
3
4
5
6
7
8
9
Note
The TALLY input from EXT I/O can be used in Legacy mode
and Bridge mode. It is disabled in MCS mode.
23
Signal name
Specifications
PREVIEW S1
Contact (Max. 200 mA)
PREVIEW S2
Contact (Max. 200 mA)
PREVIEW IN
PREVIEW button input
(ON: GND, OFF: Open)
CALL OUT
CALL output
(Open-collector, Max. 30 mA)
TALLY ENABLE
ON: GND
R TALLY IN
R TALLY IN
PREVIEW IN/
G TALLY IN
G TALLY IN
POWER IN
Power supply input (10.5 V to 30 V)
GND
GND
OFF: Open
PREVIEW IN

Advertisement