ASM positape WBT Series Installation And Operation Manual

ASM positape WBT Series Installation And Operation Manual

Combined displacement and inclination sensors

Advertisement

Quick Links

®
positape
WBT Series
Combined displacement and inclination sensors
Installation and operation manual
EN
Please read carefully before installation and operation!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the positape WBT Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ASM positape WBT Series

  • Page 1 ® positape WBT Series Combined displacement and inclination sensors Installation and operation manual Please read carefully before installation and operation!
  • Page 2 © ASM Automation Sensorik Messtechnik GmbH, 2020 All rights reserved. Am Bleichbach 18 - 24 85452 Moosinning Germany...
  • Page 3: Table Of Contents

    3.3 Operating temperature ......................... 14 4 Maintenance and disposal ..................15 4.1 Maintenance and repair ....................... 15 4.2 Disposal ............................15 5 Output specification ....................16 5.1 Measurement signal and range....................16 5.2 Digital interface CANopen ......................17 Version 2.1.0 www.asm-sensor.com...
  • Page 4: Safety Instructions

    Disregarding the following instructions may result in malfunction, damage to property and personal injury and releases the manufacturer from product liability. Safety regulations • National safety regulations must be observed! Pos : 9 /########### Seitenumbr uc h ################################### @ 0\m od_1353584168894_0.docx @ 336 @ @ 1 Version 2.1.0 www.asm-sensor.com...
  • Page 5: General Safety Instructions

    Do not pull out the measuring tape beyond the range of the sensor. Malfunction due to the accumulation of dirt on the measuring tape Do not oil or lubricate the measuring tape. • Pos : 12 /########### Sei tenum bruch ################################### @ 0\mod_1353584168894_0.docx @ 336 @ @ 1 Version 2.1.0 www.asm-sensor.com...
  • Page 6: Intended Use

    Avoid bending the tape stop while packing the sensor. Shipment content Sensor • Installation and operation manual • Pos : 16 /########### Sei tenum bruch ################################### @ 0\mod_1353584168894_0.docx @ 336 @ @ 1 Version 2.1.0 www.asm-sensor.com...
  • Page 7: Installation And Initial Operation

    30 cm from the tape outlet must be kept in axial direction. While retracting the tape, it must be twisted back at the distance of at least 30 cm before the tape entirely enters the tape outlet. Version 2.1.0 www.asm-sensor.com...
  • Page 8 The deflection is possible only in one axis - on the flat side. Pulley wheels with the diameter of >15 mm are recommended (see chapter “Accessories” in the catalog positape ® Pos : 19 /########### Sei tenum bruch ################################### @ 0\mod_1353584168894_0.docx @ 336 @ @ 1 Version 2.1.0 www.asm-sensor.com...
  • Page 9 Pos : 21 /Bedienungs anl eitungen/Positape/W BT21_Befestigung @ 7\mod_1530273919863_78.docx @ 57116 @ @ 1 Sensors with holes in the base plate Model Screw Screw material Torque [Nm] WBT21 WBT21 Pos : 22 /########### Sei tenum bruch ################################### @ 0\mod_1353584168894_0.docx @ 336 @ @ 1 Version 2.1.0 www.asm-sensor.com...
  • Page 10 The mounting option can be set by the user via software. Sensor position as shown equals 0°. WBT21 Mounting option 1 Mounting option 2 Mounting option 3 Output signal Pos : 24 /Bedienungs anl eitungen/Positape/Kennlinie_WBT61_85 @ 8\mod_1569316673928_78.doc x @ 67986 @ @ 1 Version 2.1.0 www.asm-sensor.com...
  • Page 11 The mounting option can be set by the user via software. Sensor position as shown equals 0°. WBT61 / WBT85 Mounting option 1 Mounting option 2 Mounting option 3 Output signal Pos : 25 /########### Sei tenum bruch ################################### @ 0\mod_1353584168894_0.docx @ 336 @ @ 1 Version 2.1.0 www.asm-sensor.com...
  • Page 12: Electrical Connection

    It is important that the knurled nuts on the connectors are tightened to the correct • torque for each different size of the connector: • M12-ASM connectors / couplings: 1.0 Nm connectors / couplings of other manufacturers: according to manufacturer • instruction.
  • Page 13 A separate cord grip for cable strain relief is recommended Observe cable routing in case of splashing water, water condensation and humidity Pos : 29 /########### Sei tenum bruch ################################### @ 0\mod_1353584168894_0.docx @ 336 @ @ 1 Version 2.1.0 www.asm-sensor.com...
  • Page 14: Operating Temperature

    Pos : 31 /Bedienungs anl eitungen/Positape/Arbeitstem per atur_Ü bersic ht_WBT @ 7\m od_1530273489421_78.docx @ 57105 @ 2 @ 1 3.3 Operating temperature positape WBT61 -40 … +85°C ® positape WBT85 -40 … +85°C ® positape WBT21 -40 … +85°C ® Pos : 32 /########### Sei tenum bruch ################################### @ 0\mod_1353584168894_0.docx @ 336 @ @ 1 Version 2.1.0 www.asm-sensor.com...
  • Page 15: Maintenance And Disposal

    Mounting elements Tighten mounting parts with recommended torque, if applicable use bolt adhesive Measuring tape Damaged tape, (e.g. bended tape): send sensor to ASM for repair Opening the following sensors will cause damage and void the warranty: positape WBT61 •...
  • Page 16: Output Specification

    Measurement range corresponds to a digitally coded number (resolution eg. 10 steps / mm). Position 100% Measurement value 0 steps 3,000 steps 10,000 steps (example) Pos : 40 /########### Sei tenum bruch ################################### @ 0\mod_1353584168894_0.docx @ 336 @ @ 1 Version 2.1.0 www.asm-sensor.com...
  • Page 17: Digital Interface Canopen

    0.5 kHz Stability (temperature) ±50 x 10 /°C f.s. (typical) Repeatability 1 LSB Operating temperature See specification of the respective sensor Protection Reverse polarity, short circuit Dielectric strength 1 kV (V AC, 50 Hz, 1 min.) EN 61326-1:2013 Version 2.1.0 www.asm-sensor.com...
  • Page 18 Pos : 43 /Bedienungs anl eitungen/Positape/C ANopen_s pec _W S_W B/CAN op_setup @ 7\mod_1527003732700_78.docx @ 56023 @ @ 1 CANopen – Set up (MCANOP) Download • A detailed specification of this interface can be downloaded from the ASM website: www.asm-sensor.com/en/downloads.html > Configuration files Risk of injury by unexpected machine movement •...
  • Page 19 No deflection Standards Failure rate of electronic components SN 29500 (Siemens) = Reference Conditions: Reference Supply Voltage UB = 24 V, Reference Temperature ϑ = 60 °C === Ende der Liste für T extm arke Inhalt === Version 2.1.0 www.asm-sensor.com...
  • Page 20 Tel. +44 845 1222-123 Germany Tel. +49 8123 986-0 Fax +1 630 832-3204 Fax +44 845 1222-124 Fax +49 8123 986-500 info@asmsensors.com info@asm-sensor.com info@asm-sensor.com © ASM Automation Sensorik Messtechnik GmbH, 2020 All rights reserved. Subject to changes without notice. See protection note DIN34.

This manual is also suitable for:

Positape wbt61Positape wbt85Positape wbt21

Table of Contents