Setting up the file transfer protocol options

1.
Select "5: SPP PARAMETER" at the SET BLUETOOTH menu and
then press the ENT key.
The current settings are displayed.
"1: SERIAL No.":
"ON":
"OFF":
"2: H.PARITY":
"ON":
"OFF":
"3: LINKUP TIME":
Sets up the timeout period (in seconds) for the data link establishment.
"4: FIELD SPACE":
"Ignore": Ignores the trailing spaces in data fields.
"Data":
When changing the setting
(1) Use the cursor keys ([▲] [▼]) or numeric keys ([1] [2] [3] [4]) to select the desired menu.
(2) Press the cursor keys ([◄] [►]) to highlight and set the desired setting.
(3) Press the ENT key.
Press the BS/C key to return to the SET BLUETOOTH menu.
− Point −
The "SERIAL No" and the "H.PARITY" settings are ignored when the BHT-Ir protocol or the
Ymodem protocol is selected as the communication protocol.
152
Adds serial numbers to data blocks.
Does not add serial numbers to data blocks
Adds a horizontal parity.
Does not add a horizontal parity.
Treats the trailing spaces as data.