11. List of events which can be reported to your phone and their factory default settings

uu
00
Alarm after powering up the system
01
Instant loop alarm
02
Delayed loop alarm
03
Fire alarm
04
Panic alarm
05
Tamper alarm
06
Number of permitted incorrect code-entries exceeded
07
Device fault
08
Complete setting
09
Complete unsetting
12
Codeless setting
13
Partial setting A
14
Detector communication failure
15
Control panel power supply dropout
16
Control panel power supply restored
17
Detector power supply dropout
18
Communicator failure
19
Communicator OK
20
Control panel battery failure
21
Control panel battery OK
23
Alarm 24h
24
Receiver jamming
Setting A – split system
26
Setting B – split system
27
Unsetting A – split system
28
Unsetting B – split system
29
33
Partial setting AB
50
Low SIM card credit balance
51
Image delivered to server (e.g. from JA-84P)
64
Power supply ON
65
Switching to service / maintenance mode
66
Exiting service / maintenance mode
67
End of alarm indication
78
Alarm cancelled by user
79
Control panel reset
80
All tampers on standby
81
All faults removed
82
System power supply OK
83
The communicator has no connection
84
Communicator connection restored
85
Master code reset to 1234
86
Master code changed
68
Reporting to ARC1
69
No reporting to ARC1
89
Power supply failure exceeding 30 minutes
90
Unconfirmed alarm
91
Service request
92
PgX output ON
93
PgX output OFF
94
PgY output ON
95
PgY output OFF
96
Blocking after an alarm (Engineer reset)
97
Unblocking after an alarm
Notes:
 Factory default report assignment: S = SMS, C = call, SC = SMS followed by a call
 "External communication fault" means a GSM network dropout longer than 15 minutes (if GSM network dropout indication is enabled)
 To get an SMS (from the JA-84P) with a picture link, enable event 51
 In a split system it is necessary to synchronize the current control panel settings by opening enrollment mode for 1 s and closing it before you leave service mode
 In a split system telephone memory positions are associated with certain sections for reporting alarms as below:
o
1st telephone number: sections A, B, C (administrator/master)
o
2nd to 4th telephone numbers: sections A, C
o
5th to 7th telephone numbers: sections B, C
o
8th telephone number sections: A, B, C (service technician)
The JA-82Y GSM communicator installers manual
Event
tab. 5 List of events which can be reported to your phone and their factory default settings
Telephone number memory - M
ABC
AC
1
2
3
4
SC
SC
SC
S
SC
SC
SC
S
SC
SC
SC
S
SC
SC
SC
S
SC
SC
SC
S
SC
SC
SC
S
SC
SC
SC
S
S
S
S
S
SC
SC
SC
S
S
S
S
S
S
S
S
10/13
BC
ABC
5
6
7
8
SC
SC
S
SC
SC
S
SC
SC
S
SC
SC
S
SC
SC
S
SC
SC
S
SC
SC
S
S
S
S
S
SC
SC
S
S
S
S
Voice message
5: "fault"
1: "intruder alarm"
1: "intruder alarm"
2: "fire alarm"
4: "panic alarm"
3: "tamper alarm"
3: "tamper alarm"
5: "fault"
"Armed system"
"Disarmed system"
"Armed system"
"Partially armed"
5: "fault"
7: "other event"
7: "other event"
5: "fault"
5: "fault"
7: "other event"
5: "fault"
7: "other event"
1: "intruder alarm"
5: "fault"
"Armed system"
"Armed system"
"Disarmed system"
"Disarmed system"
"Partially armed"
5: "fault"
7: "other event"
7: "other event"
7: "other event"
7: "other event"
7: "other event"
7: "other event"
7: "other event"
7: "other event"
7: "other event"
7: "other event"
5: "fault"
7: "other event"
7: "other event"
7: "other event"
7: "other event"
5: "fault"
5: "fault"
7: "other event"
7: "other event"
7: "other event"
7: "other event"
7: "other event"
7: "other event"
7: "other event"
7: "other event"