User Communicator Programming; Voice Menu For Control Via A Telephone; Installation Programming - jablotron JA-82Y Installer Manual

Gsm communicator
Hide thumbs Also See for JA-82Y:
Table of Contents

Advertisement

3.4. Remote control by unanswered calls
A limited number of system functions can be activated remotely by calling the
system from pre-authorized phones. It is possible to pre-authorize phone numbers
stored in memories M1 to M8 (also used for event reporting – see 4.1). To pre-
authorize a telephone number insert  at the end of the number and follow it by a
single digit (1, 2, 3, 8 or 9) – see the notes in section 4.1. If such a number calls, the
communicator enters a " digit" sequence in the system after the first ring (as if it
had been entered manually on the system keypad). This remote control by
unanswered calls enables the following functions:
1
setting the complete system (identical to ABC button)
2
A section setting (identical to A button)*
3
A and B or just B section setting (identical to B button)*
8
PGX turns on for 2 sec (if PGX is programmed for the 2s pulse
function)
9
PGY turns on for 2 sec (if PGY is programmed for the 2s pulse
function)
Notes:
if a phone sends no caller identification data it cannot be used for this type
of remote control by phone
 when using remote control by unanswered calls, and if the sequence 85 M0
has been entered, the communicator terminates the call itself, so that remote
control is free of charge
 a phone which is pre-authorized for remote control by unanswered calls can
also temporarily authorize its keypad to fully operate the system (see 3.2) – just
cancel the action controlled by an unanswered call
 if it is desired that the phone which is authorized for toll-free remote control
should not receive event reports, then turn the reports off for that tel. number
(see 6.3)
 the *X functions must be enabled in the control panel
 inserting *X is used when programming a function using a keypad, the OLink
software has a special section for this

4. User communicator programming

User setting of the communicator is performed by entering sequences from the
OASiS system keypad. Selected parameters can also be controlled or set by SMS
instructions or via OLink.
Setting on the system keypad is possible only in the case that the control panel is in
maintenance mode (if it is not, enter *0 master code – Factory default setting
1234). Modification of values set in the communicator is performed by entering
programmable sequences (see Tab. 7).
Press the # button to exit Maintenance mode or to cancel code entering when
you key in a wrong number.
If setting of telephone numbers in Maintenance mode is enabled in the control
panel settings (sequence 251 of the OASiS control panel), then it is possible to set
the following communicator parameters in Maintenance mode by keying in the
below mentioned sequences beginning with 8:
 Set telephone numbers M1 to M7
 Assign codes for control by SMSes without having to enter the code
 Select events which should be reported by an SMS message and calling
 Enable / disable remote access (full access or single numbers)
 Measure GSM signal strength
 Limit the number of sent SMSes
 Set forwarding of incoming SMSes to the first set telephone number
 Restart the GSM communicator
 Record voice messages
 Change remote access code
4.1. Setting of telephone numbers for reporting
The communicator reports events in the OASiS system by sending a text SMS and
/ or calling and transmitting a voice message. Reporting can be programmed for
to up to 8 telephone numbers.
The most frequently desired reports are already assigned to the telephone number
memories by factory-default, so you only need to program tel. numbers to the
particular memories:
Overview of reports assigned to tel. numbers (this can be modified see 6.4)
M
Communicator´s own SIM card number
0
1
Alarms by SMS and phone call, faults by SMS (ABC)
Poplachy SMS zprávou
2
Alarms by SMS and phone call (AC)
Technické zprávy odesláním SMS (pro servisního technika)
3
Alarms by SMS and phone call (AC)
Alarms by SMS (AC)
4
5
Alarms by SMS and phone call (BC)
6
Alarms by SMS and phone call (BC)
7
Alarms by SMS (BC)
8
Technical faults by SMS (for a service technician) (ABC)
tab. 2 Reports assigned to telephone number memories M1to M8
To program phone numbers to the M memories, enter the following sequence
while in Maintenance / Service mode:
81 M xxx...xy 0
The JA-82Y GSM communicator installers manual
Reports
where:
M
is memory number 1 to 8
xxx...x
is a telephone number (max. 20 digits)
y
is a sequence for control via unanswered calls
(it does not have to be entered)
In a split system, information from all sections (ABC) is reported to the 1st
and 8th number positions, sections AC to numbers 2 to 4, and from sections
BC to positions 5 to 7, shown in OLink software by colour differences
Notes:
 In a split system, when you change a detectors section, adjust the reaction of
the detector etc, you have to enter enrollment mode for 1s and leave it before
you leave service mode. This way the changes are saved in the communicator.
 For automatic time synchronizing by SMS use position 0 in the telephone
number settings (the position for its own SIM card number). When you change
the SIM card this number will be automatically erased.
To erase a number from memory M enter: 81 M 0
: entering 81 5 777 777 777 0 will store the number 777777777 in
Example 1
memory M5 (alarms will be reported by SMSes + phone calls with a voice
message) Setting/Unsetting will only be reported by an SMS). Remote access is
allowed for this telephone number.
: entering 81 1 777 777 777 8 0 will store the number 777777777 in
Example 2
memory M1 (alarms will be reported by SMSes only.) Calling from this number will
turn on PgX for 2s. Remote access is not allowed to this telephone number.
Notes:
 Entering *9 before the first digit will insert a "+" for the international formatting of
phone numbers
 SMS report text consists of the installation name, event type, name of the event
source, date and time. For example: „Report from your alarm: setting 47:
device Time 11:27 01.08 "
 if other events or texts should be reported to a particular number, change the
communicator settings (see 6.4, 6.7 and tab. 5 the list of events which can be
reported to your phone and their factory default settings)

5. Voice menu for control via a telephone

The communicator is equipped with a voice menu for remote control of the basic
system functions (remote access via a telephone must be enabled). The menu has
factory default voice reports in multiple languages – the desire languages selected
by keying in the 991 xx sequence ( see 6.1). The voice menu function (Fig. 2 Voice
menu scheme ) is as follows:
 after 15 seconds of ringing the communicator will answer with a voice
menu welcome message.
 After entering valid code the voice menu offers setting or unsetting. The
offer is played once and if you press any key, the current status is reported
and the current offer replayed.
 If you press 9 in the menu, you will hear: "Keypad simulation" and the
telephone will start acting as a system keypad. It will remain in this mode
making it possible to enter sequences which are confirmed by beeping.
 When you enter the service / maintenance code verification is performed
and if the code is valid, you will hear: "Service mode, keypad simulation". It
remains in this mode and you can enter keys which are confirmed by
beeping. If you key in 892 now, you will enter voice message recording
menu – see 10.
 Events happening during remote access are reported once every 5 secs

6. Installation programming

The most convenient and complete programming is best done by a PC running
OLink software connected locally in the installation or remotely via the Internet.
The communicator can also be programmed by keying in sequences from the
OASiS system keypad or via SMS programming instructions.
Programming by the system keypad is possible only if the control panel is in
Service mode, if it is not, key in *0 Service code (factory default setting: 8080) with
the alarm system unset (disarmed) The setting is performed by keying in
programming sequences, (see Tab. 7 communicator programming sequences).
Press the # button to exit service mode or to cancel code entering when you
key in a wrong number.
6.1. Communicator language setting
The language of the texts and voice menu used by the communicator can be set
by the instruction:
991 xx
where: xx is a number defining the language – see the following list:
0
E
English
1
N
0
CZ Czech
2
0
SK Slovak
3
0
NL Dutch
4
0
D
German
5
E
0
PL Polish
6
2/13
1
FI
Finish
0
1
N
Norwegian
1
O
1
SV
Swedish
2
1
FR
French
3
1
HU Hungarian
4
1
RU Russian
5
MDL51109

Advertisement

Table of Contents
loading