Important notes
1.1.2

Protection against contact with electrical parts and housings

Bosch Rexroth AG R911319998_Edition 05
This section concerns components of the electric drive and
control system with voltages of more than 50 volts.
Contact with parts conducting voltages above 50 volts can cause personal
danger and electric shock. When operating components of the electric drive
and control system, it is unavoidable that some parts of these components
conduct dangerous voltage.
High electrical voltage! Danger to life, risk of injury by electric shock or
serious injury!
Only qualified persons are allowed to operate, maintain and/or repair the
components of the electric drive and control system.
Follow the general installation and safety regulations when working on
power installations.
Before switching on, the equipment grounding conductor must have
been permanently connected to all electric components in accordance
with the connection diagram.
Even for brief measurements or tests, operation is only allowed if the
equipment grounding conductor has been permanently connected to the
points of the components provided for this purpose.
Before accessing electrical parts with voltage potentials higher than
50 V, you must disconnect electric components from the mains or from
the
power
supply
reconnection.
With electric components, observe the following aspects:
Always wait 30 minutes after switching off power to allow live capacitors
to discharge before accessing an electric component. Measure the
electrical voltage of live parts before beginning to work to make sure
that the equipment is safe to touch.
Install the covers and guards provided for this purpose before switching
on.
Never touch any electrical connection points of the components while
power is turned on.
Do not remove or plug in connectors when the component has been
powered.
Under specific conditions, electric drive systems can be operated at
mains protected by residual-current-operated circuit-breakers sensitive
to universal current (RCDs/RCMs).
Secure built-in devices from penetrating foreign objects and water, as
well as from direct contact, by providing an external housing, for
example a control cabinet.
High housing voltage and high leakage current! Danger to life, risk of injury
by electric shock!
Before switching on and before commissioning, ground or connect the
components of the electric drive and control system to the equipment
grounding conductor at the grounding points.
IndraDrive Supply Units HMV01
unit.
Secure
the
electric
component
from