2.2

HMV01.1R

Description
Listing in accordance with UL
standard
Listing in accordance with CSA
standard
UL files
Pollution degree
Ambient temperature range with
nominal data
Ambient temperature range with
reduced nominal data
Mass
Device height
1)
Device depth
2)
Device width
3)
Minimum distance on the top of
the device
4)
Minimum distance on the bottom
of the device
5)
Horizontal spacing at the device
Rated control voltage input
7)
Rated power consumption control
voltage input at U
8)
N3
Short circuit current rating
Rated input voltage, power
9)
Tolerance rated input voltage U
Mains frequency
Tolerance input frequency
Rated input current
Branch circuit protection fuse
Required wire size in accordance
with NFPA 79 and UL 508 A
(internal wiring);
11)
Field wiring material (material;
conductor temperature; class)
Output voltage
UL ratings and dimensions
Symbol
Unit
T
°C
amax
T
°C
amax_red
m
kg
H
mm
T
mm
B
mm
d
mm
top
d
mm
bot
d
mm
6)
hor
U
V
N3
P
W
N3
SCCR
A rms
U
V
LN_nom
LN
f
Hz
LN
Hz
I
A
LN
10)
A
AWG
LN
U
V
out
HMV01.1R-
HMV01.1R-
W0018
W0045
UL 508C
C22.2 No. 274-13
E134201
13.50
20.00
175
250
130
DC 24 ±5 %
31
41
42000
3 x AC 380...480
50...60
26.0
65.0
40
80
10 AWG
6 AWG
Cu; 60/75 °C; 1
DC 750
R911319998_Edition 05 Bosch Rexroth AG
Ratings and dimensions
HMV01.1R-
HMV01.1R-
W0065
W0120
2
40
55
31.00
34.50
440
262
350
300
334
0
108
224
±2
94.0
181.0
110
225
3 AWG
3/0 AWG
Latest amendment: 2017-01-20