1 INSTALLATION Vertiv™ offers optional monitoring packages for the Liebert® MBX Busway System End Feed Box and Tap- Off Box using Socomec DIRIS Digiware. • End Feed Box Only Package: Includes DIRIS Digiware G-30, I-45 and U-30 • End Feed Box and Tap-Off Box Package: Includes DIRIS Digiware G-30, I-45, U-30, I-30 and C-31 interface module.
Set the baud rate, stop bits and parity. The default settings are 38400/1/N. On U-30 Modules, click the Network Tab . Confirm the power system settings are correct for the customer site: Vertiv™ | Liebert® MBX Monitoring Installer/User Guide...
Page 7
• Network Type • Nominal Voltage • Frequency • Phase Rotation NOTE: Record the serial number of each G30 Module for future reference. 9. G-30 Only: Click the Device Detection Tab . 10. G-30 Only: Click the New Discovery Button and wait till the discovery is complete, approximately 3 minutes.
Page 8
This page intentionally left blank Vertiv™ | Liebert® MBX Monitoring Installer/User Guide...
2 TAP-OFF BOX MONITORING If your Tap-Off Box is equipped with a monitoring option, there will be two RJ-45 jacks on the side of the enclosure. The Tap-Off Box RJ-45 connections must be daisy-chained from Tap-Off Box to Tap-Off Box with the final connection made at the End Feed Box that houses the gateway device.
Page 10
5. Click Send to Device . 6. Select the G-30 Module and click Connect To Device . 7. Click Select All then Click Ok . 8. Wait for the configuration to be sent. Click Ok . Vertiv™ | Liebert® MBX Monitoring Installer/User Guide...
3 WEB PORTAL CONFIGURATION After completing all the I-module configurations or after adding a new Tap-Off Box Module to a busway run, you must log in into the Socomec web portal and update the configuration. Click the Change Profile Button in the upper right corner. 2.
Page 12
This page intentionally left blank Vertiv™ | Liebert® MBX Monitoring Installer/User Guide...
4 FIRMWARE UPDATE If the firmware for each device is not the latest available on the Socomec website, download the firmware ZIP file for the module(s) to be updated. Firmware versions may be checked on the Socomec website: https://www.socomec.com/product-upgrade-tool-software_en.html . To update a Socomec Digiware module firmware, perform the following steps: Download the latest version of Socomec’s Product Upgrade Tool and firmware version from the page above.