Operation - Omron H8BM-R Series Quick Start Manual

Multi-maintenance counter/timer
Table of Contents

Advertisement

Operation

Key protection and whether each counter operates as a counter or a timer are specified on a DIP switch provided on the side panel of the
Counter. Open the cover of the switch compartment on the side of the Counter to access the DIP switch.
Timer
Counter
DIP switch compartment
The system will always enter the RUN mode after the power supply is turned ON.
SET
Key
Press for 4 s min.
Re-monitor mode
Refer to page 12 for
information on the
re-monitor mode.
1. DIP Switch Settings
Enabled
1
2
3
4
5
6
7
8
9 10
Key Protection
(Can always be switched.)
Disabled
2. Changing Mode
Normal Mode
This mode is for the operational state.
RUN mode
The present value, set value, counter number,
and output status will be displayed.
MODE
Key
3
200000
This mode is for setting forecast values.
Forecast value mode
Values can be independently set for each
counter number.
MODE
Key
3
200000
This mode is for setting pre-forecast values.
Pre-forecast value mode*
The pre-forecast will be displayed (LCD) as a value before
the forecast value. Set that value as the pre-forecast value.
Values can be independently set for each counter number.
Set the pre-forecast value by deviation.
MODE
Key
3
--
This mode is for setting machine stoppage values.
Machine stoppage mode*
Machine stoppage (output/LCD) will occur at a value in
excess of the forecast value. Set that value as the
machine stoppage value.
Values can be independently set for each counter number,
but machine stoppage output will be performed if any
counter from No. 1 to 9 reaches the machine stoppage
MODE
Key
value. Set the machine stoppage value by deviation.
3
Note 1. Set the DIP switch (except for Key Protection) before turning
ON the power.
Changes to DIP switch settings while the Counter is operating
will be ignored. Power must be turned OFF then back ON
after changing the settings.
Changes to DIP switch settings are also enabled when
changing to initial setting mode because the same operation
is performed as when cycling the power.
2. Key protection can be set for each key. Key protection will be
performed based on the details set in the initial setting mode.
Refer to Initial Setting Mode on page 11.
MODE
Press for 4 s min.
23456
23456
23456
500
23456
10000
H8BM-R
Key
Initial Setting Mode
Refer to page 11 for
information on the initial
setting mode.
Note: I/O operations are always performed regardless
of the mode.
If no key is pressed for 1 minute in each mode,
the RUN mode is automatically restored.
3
will flash.
The modes marked * are not provided on the 1-
stage type Counter.
8

Advertisement

Table of Contents
loading

Table of Contents