Indoor Unit Installation
Step 4: Adjust the air inlet direction (From rear side to underside)
1. Take off the ventilation panel and flange.
Ventilation panel
Fig. 11.
2. Change the mounting positions of the ventilation panel and air
return flange.
Air return flange
Fig. 12.
3. When installing the filter mesh, fit it into the flange as illustrated in
the following figure.
Fig. 13.
NOTE:
All the figures in this manual are for demonstration purposes only. The
air conditioner you have purchased may be slightly different in design,
though similar in shape.
10
Step 5: Fresh air duct installation
Dimension :
Air return flange
Ventilation panel
Fig. 14.
Step 6: Motor and drain pump maintenance
(The rear ventilated panel is used as an example)
Motor maintenance:
1. Take off the ventilated panel.
2. Take off the blower housing.
3. Take off the motor.
Fig. 15.
Pump maintainance:
1. Remove four screws from the drain pump.
2. Unplug the pump power supply and water level switch cable.
3. Detach the pump.
Fig. 16.
Duct joint for fresh air
MODEL
18-60
Ø125 mm
Climate 5000 SCI – 6720887422 (2019/07)
Ø160 mm
Motor
Blower housing
Ventilated panel
Pump