Installation Preparation; Selection Of Installation Location; Selection Of Installation Location For Indoor Unit - Gree U-Match Series Owner's Manual

Duct type unit
Hide thumbs Also See for U-Match Series:
Table of Contents

Advertisement

No
Name
1
Drain Plug
Drainage
2
Connecter
3 Installation

3.1 Installation Preparation

3.1.1 Selection of Installation Location

The unit must be installed where strong enough to withstand the weight of the
①.
unit and fixed securely; otherwise the unit would topple or fall off.
Install the air conditioner at a place where the inclination is less than 5°.
②.
Do not install the unit at a place with direct sunlight.
③.
Do not install where there is the danger of combustible gas leakage.
④.
Do not install the unit near heat source of heat, steam, or flammable gas.
⑤.
Selection of Installation Location for Indoor Unit (Select a location
pursuant to the following condition)
(1) Air inlet and outlet of the indoor unit should be away from obstacles to make
sure the unit's air flow can reach the entire room. Do not install the unit in a
kitchen or a laundry.
(2) Select a location that can withstand 4 times the unit weight without increasing
operating noise and vibration.
(3) The installation location must be level.
(4) The indoor piping length and wiring length should be within the allowable
range.
(5) Select a place that can easily drain condensate and connect to the drain
system of the air conditioner.
Outdoor Unit Accessories
Appearance
or
WARNING
7
U-Match Series Duct Type Unit
Q'ty
1or3 To plug the unused drain hole
To connect with the hard PVC
1
drain pipe
Usage