Advertisement

Quick Links

TIMER
POWER
Remote control AMW P - AMW ST
EN
USER INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for Riello AMW P

  • Page 1 TIMER POWER Remote control AMW P - AMW ST USER INSTRUCTIONS...
  • Page 2 This manual contains information we deem necessary for correct and easy use. Thanks again. RIELLO COMPLIANCE R AMW P - AMW ST heat pumps are compliant with the following European Directives: — Low Voltage Directive 2014/35/EU — Electromagnetic Compatibility Directive 2014/30/EU — RoHS Directive 2011/65/EU —...
  • Page 3: Table Of Contents

    AMW P ........p. 5...
  • Page 4: General Information

    GENERAl INfoRMATIoN GENERAL INFORMATION This unit contains fluorinated greenhouse gases covered General Notices by the Kyoto protocol. Maintenance and disposal activities must be carried out exclusively by skilled personnel. R32 refrigerant gas is slightly flammable and odourless. When you get the product, check immediately that the con- tents are all present and undamaged.
  • Page 5: Amw P

    The unit can be identified through the technical data plate: AMW P Unit description R AMW P is an indoor unit for wall installation, suitable for use in residential and small business premises in combination with the outdoor unit. The multiple-speed fan DC motor im- proves performance and sound comfort.
  • Page 6: Unit Display

    Temperature indication Operating mode Cooling mode enabled Power supply 1PH,230V~,50Hz Heating mode enabled Anti-electric shock Class Riello S.p.A- Via Ing. Pilade Riello, 7 Net Weight 8.8 kg 37045 LEGNAGO (VR) - Italy Air volume 500 m³/h Not available Model :...
  • Page 7: Layout

    GENERAl INfoRMATIoN layout TIMER POWER Air intake Front panel Metal cabinet Air filter Motor-driven deflectors Air outlet Electric panel cover Remote control 1. Detected ambient temperature Unit display 2. Required temperature when using the button The unit display shows the temperature and the alarms, if any. 3.
  • Page 8: Remote Control

    GENERAl INfoRMATIoN Remote control DooR oPEN Control, setting and programming operations are carried out with the IR remote control. The electronics modulates the device operation according to the temperatures detected by the probes inside the indoor and out- door units. function keys TIMER The remote control features a small door in the key area:...
  • Page 9: Remote Control Display

    GENERAl INfoRMATIoN Remote control display Motor-driven deflector settings Horizontal deflector position The remote control display shows the settings as changed by the user and the detected weather conditions. Vertical deflector position (not available on AMW The backlit display is divided in areas according to function type. Deflector automatic operation fan settings Fan speed set...
  • Page 10: Use

    Initial settings Battery insertion The remote control is powered by two AAA batteries (1.5 V) housed at the back, under a cover. Should you notice a poorer reception or if display information fades out, the batteries must be changed. To fit or change batteries: FAN MODE —...
  • Page 11: Start-Up

    The Heating mode allows starting and using the system to de- liver hot air. To activate this function, recommended outdoor temperature should be ranging from -25 °C on AMW P , -15 °C on AMW ST, to 16 °C. Required ambient temperature available range is between 16 °C and 30 °C.
  • Page 12: Dehumidification Mode

    • Activation — press Remote control and unit displays show Set required temperature as follows: — work Value is stored with no need to press other buttons. • Switch-off — select another operating mode Alternatively: — press to turn unit off Smart mode In Automatic mode, equipment automatically changes operat- ing mode, toggling between Cooling and Heating to keep a con-...
  • Page 13: Quiet Function

    • Activation — press POWER Remote control display shows • Switch-off — select another operating mode Minimum speed Alternatively: Medium speed Maximum speed — press to turn unit off Automatic speed Use with open flap — work When the door is open, you can access the advanced functions, —...
  • Page 14: Vertical Motorised Deflector

    Cooling and Dehumidification mode Initial position Heating Mode Smart mode — work Initial position — select required position Each press will select a different position. — work When selecting , position changes automatically according — select required position to preset strategies. Each press will select a different position.
  • Page 15: Health Air Flow Function

    flector so as to avoid aiming the air flow directly at persons. + 1 °C + 1 °C Sleep function on Sleep function end and unit switch-off Set temperature • Activation h Hours passed since function activation — press — increasing it in Cooling and Dehumidification mode Remote control display shows This setting is recommended for Cooling mode.
  • Page 16: Switching Unit Display Off Or On

    — aim the remote control on the side opposite to unit re- If required, indoor unit display can be turned off or on. ceiver AMW P — press The remote control turns on. — aim the remote control to unit receiver —...
  • Page 17: Selecting The Temperature Measurement Unit

    Set required time as follows: Factory set channel is A. Select required channel as follows: — work — work — Each time the key is pressed, the values changes by 1. by Each press will select a different channel, toggling between A keeping the key pressed down, the value changes faster.
  • Page 18: Temporary Shutdown

    O F F — set the system main switch to “OFF” Maintenance Routine maintenance is fundamental for keeping the equip- ment efficient, safe and reliable. It can be performed periodi- cally by R Technical Support Service, whose staff is technical- ly qualified and can use genuine spare parts, if necessary.
  • Page 19 Mesh filters Mesh filters Air purifying filter — open the front panel — remove exhausted purifying filters — take out the mesh filter by grabbing the relevant fins — insert new purifying filters into the prearranged slots — remove exhausted purifying filters if present —...
  • Page 20: 2.10 Troubleshooting

    2.10 Troubleshooting Power failure If unit display does not turn on after you press remote control, and equipment does not turn on, ensure that: — equipment power plug, if any, is properly plugged — system main switch is set to “ON” —...
  • Page 21 fault codes for outdoor unit Indoor code outdoor unit led Description Remarks indication 1 flashing After 3 consecutive interventions in 10 minutes, Power module fault the unit resets after problem resolution Compressor motor overcurrent The unit resets automatically Communication error between main The alarm activates 4 minutes after the unit start board and power module The unit resets after problem resolution...
  • Page 22 faults requiring intervention of the Technical Support Service If any of these faults occurs: — the power cable is too hot or damaged — a strange noise is heard during operation — either the cut-out, a fuse or grounding switch is tripping all the time —...
  • Page 23 RECyClING AND DISPoSAl DISPoSAl Packing materials must be disposed of separately, in order to be recovered and recycled. Equipment at end of life and flat bat- teries must be disposed of as required by prevailing law and regulations.
  • Page 24 RIELLO S.p.A. - 37045 Legnago (VR) tel. +39 0442 630111 - fax +39 0442 630371 www.riello.it As the manufacturer is constantly improving its products, the aesthetic or dimensional features, the technical data, the equipment and accessories indicated could be subject to variations.

This manual is also suitable for: