8.2.4 INITIALIZE MODE

Operation item
A
No.
1
SYNC DET(+)
2
SG MODE
3
SG PATTERN
4
SIDE MASK LEVEL(+)
5
FINAL SETUP(+)
6
HMG/HG SERVICE MODE
B
7
CVT AUTO
8
HDMI INTR POSITION(+)
Note : When there is an altered history due to an open TRAP SW, if the "DISPLAY" key is held for at least
5 seconds on the above menu, the altered history will be cleared and the unit will be back to normal.
8.2.4.1 SYNC DET(+)
Exclusively used for technical analsyis (details omitted).
C
8.2.4.2 SG MODE
SG MODE (SG's route selection)/SG PATTERN (signal pattern selection) are used as pair.
In SG MODE, select the SG route and then select the SG pattern to be sent by the selected
route. In SG MODE, make sure to select the route first.
D
E
No.
1
SG OFF
2
DIG MVDEC YCBCR
3
ANA MVDEC YCBCR
4
ANA MVDEC Y
5
ANA AD YCBCR
6
ANA AD RGB
F
156
1
2
Display
Exclusively used for technical analsyis.
Paired SG_MODE with SG_PATTERN.
Select SG Route.
Paired SG_MODE with SG_PATTERN.
Select SG Pattern.
Configure the color of the side mask.
Initialize flash memorys on virgin product status
Enter HMG/HG SERVICE MODE
Exclusively used for technical analsyis.
Exclusively used for technical analsyis.
Display
SG Mode is OFF.
MAIN VDEC: YCbCr (Digital output mode)
MAIN VDEC: YCbCr (Analog output mode)
MAIN VDEC: Y (Analog output mode: SG VDEC return setting)
AD: YCbCr
AD: RGB
PDP-5071PU
2
3
Content
RS232C
Content
3
4
-
-
-
BSL
GSL
RSL
FST
-
-
-