Pioneer PDP-5071PU Service Manual page 120

Plasma display system
Table of Contents

Advertisement

1
A
Initial setting
After turning the unit on, enter Factory mode.
B
Voltage setting
Set VOL SUS to 137 (Vsus = 205 V).
C
VOL RST P: Set to the voltage indicated on the panel label.
(See the conversion table for the electronic VR.)
VOL OFFSET: Tentatively set to the voltage indicated on the
panel label. (See the conversion table for the electronic VR.)
D
Aging
Perform aging with the fully white screen for 30 minutes
E
F
120
1
2
1 Preparations
Display RST MASK 01 (white).
(To 2 )
PDP-5071PU
2
3
FAY
with command
PAV S00
VFQ S03
WBI S01
PGM S00
MKS S51
Note:
To prevent an error caused by the temperature
characteristics and to let the unit show its full properties
after letting it sit, perform aging for 30 minutes to raise
the panel temperature to a certain extent.
This ensures the accuracy of inspection and adjustment.
3
4
4