LG MULTI V IV ARNU07GTU 2 Series Service Manual page 102

Hide thumbs Also See for MULTI V IV ARNU07GTU 2 Series:
Table of Contents

Advertisement

Troubleshooting Guide
Error
Error Type
No.
34*
Master
341
Over-increase of dis-
Slave1
charge pressure of
342
compressor
Slave2
343
Slave3
344
n Error diagnosis and countermeasure flow chart
Is service valve opened ?
Yes
Are communication
cable / pipe connection
normal?
Yes
Is refrigerant
amount normal?
[refer refrigerant part]
Yes
Is fan normal?
(Indoor fan during heating
Outdoor fan during cooling)
Yes
Is filter blocked
(Heating:indoor,
Cooling:outdoor
heat exchanger)?
Yes
Is value of high pressure
sensor same as Manifold
value(Is it high actually)?
Yes
Check indoor unit LEV
Check indoor unit PCB
Check in/outdoor installation
condition
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Error Point
Error happens
because of 3 times
successive compres-
sor off due to over-
increase of high pres-
sure by high pressure
sensor
No
Open service valve
No
Check and repair communication
cable / pipe connection
No
Adjust refrigerant amount
No
Replace related parts
(Refer to Error 105~107)
No
Clean indoor filter (heating)
/outdoor heat exchanger (cooling)?
No
Replace sensor of high pressure
- 102 -
Main Reasons
1. Defect of high pressure sensor
2. Defect of indoor or outdoor unit fan
3. Deformation because of damage of refrigerant pipe
4. Over-charged refrigerant
5. Defective indoor / outdoor unit EEV
6. When blocked
- Outdoor unit is blocked during cooling
- Indoor unit filter is blocked during heating
7. SVC valve is clogged
8. PCB defect of outdoor unit
10. Indoor unit pipe temperature sensor defect
LGE Internal Use Only

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multi v iv arnu09gtu 2 seriesMulti v iv arnu12gtu 2 seriesMulti v iv arnu05gtr 2 seriesMulti v iv arnu07gtr 2 seriesMulti v iv arnu09gtr 2 seriesMulti v iv arnu12gtr 2 series ... Show all

Table of Contents