Step 1) Press "Calibrate Wheel Sensor"
Step 2) Mark the starting position of the wheel
Step 3) Move until the sensor is aligned (it will show on screen when ready)
Step 4) Drive until 100 sensor pulses are achieved. The screen will show a
countdown.
Step 5) when you have achieved enough pulses, align the sensor again.
Then press "Go Next".
Step 6) Measure and enter the distance travelled.
Section 3 - Seed calibration:
Step 1) Choose your settings
Choose what seeds and/or fertilizer you
want to sow first, and what rate (in kg/ha)
you want to sow at. The front box (1) usually
holds seed, and the rear (2) fertilizer. In
"Configure Bins" you can choose these
variables and perform a calibration.