c) Battery ring terminals
• Two LED indicators:
a) Red Fault LED
b) Green Charge Status LED
• Fully automatic; powers on when needed, powers off when battery is fully-charged or topped-off
• Built-in circuit protection guards against overcharging or short circuit
• Automatically checks for correct polarity (requires a minimum of 2.0 volts battery voltage)
• Convenient, color-coded ring terminals/clamps for easy, correct installation
• Charges with high frequency, pure DC current
Battery Maintainer and Components
110/120 VOLT
AC PLUG
BLACK (NEGATIVE, –) CLAMP
BM3B_ManualENFRSP_040111.indd 6-7
CHARGE
6 VOLT / 12 VOLT
STATUS LED
SWITCH
INDICATOR
FAULT LED
INDICATOR
RED (POSITIVE, +) CLAMP
CHARGER CONNECTORS
DC ACCESSORY
PLUG
BATTERY TERMINAL RINGS
6
LED INDICATORS
Red (Fault): bad connection, battery not able to accept charge, reverse polarity hook-up
Green (Charge Status): Blinking – connection correct and charging; Solid – fully charged
6 VOLT / 12 VOLT SWITCH
The unit has two voltage rate settings (6v, 12v) controlled by one switch. Set the switch to either 6v
or 12v depending upon the battery you are charging.

sETTING Up THE UNIT

Ensure that all installation and operating instructions and safety precautions are understood and
carefully followed by anyone installing or using the maintener. Follow the steps outlined in the
"Important Safety Instructions" section of this manual.
Mounting Instructions
BM3B battery maintainer is designed to be able to mount to flat surface. The unit has incorporated
two mounting holes at the corners of the unit.
Note:
Always disconnect the maintainer at AC power source and at battery terminal when mounting the unit.
TO MOUNT THE UNIT:
1. Make sure the surface is flat and free of obstruction so the unit can rest flat on the surface.
2. Make sure the unit is disconnected from both AC power source and the battery.
3. Use 8/32 inches (6.35mm) wood screw to mount the unit through the mounting hole.
4. Do not over tighten the screw, it will damage the housing.
WARNING: Do not put the screw through the plastic housing as this will permanently damage the
unit and cause a potential electrical hazard.
OpERATING INsTRUCTIONs
IMPORTANT: ALWAYS disconnect the AC power cord from the AC power outlet before connecting (or
disconnecting) the charger to (or from) the battery.
Connecting the Maintainer and Maintaining the Battery with the Battery Clamps
The charger's output leads have color-coded battery clamps (RED-POSITIVE and BLACK-NEGATIVE).
1. Unplug the battery maintainer AC cord from the AC outlet.
2. Disconnect the battery clamps from the unit at output cord connector.
3. Connect the RED POSITIVE clamp to the POSITIVE post of the battery.
4. Connect the BLACK NEGATIVE clamp to the NEGATIVE post of the battery.
5. Connect the battery clamp connector with the unit connector, as far away from the battery as
possible.
6. Slide the voltage selector to proper setting and plug the AC cord into the AC outlet.
7. Observe blinking GREEN LED, indicates unit is operating.
8. Leave the unit on.
9. Monitor the battery from time to time.
WARNING: FOLLOW THE STEPS OUTLINED IN "IMPORTANT SAFETY INSTRUCTIONS" AT THE
FRONT OF THIS MANUAL TO REDUCE RISK OF A SPARK NEAR THE BATTERY.
Connecting the Maintainer and Maintaining the Battery with the Terminal Rings
CONNECTING THE CHARGER WITH TERMINAL RINGS
The charger's output leads have crimped, color-coded terminal rings (RED-POSITIVE and BLACK-
NEGATIVE). These rings connect directly to the corresponding connectors on the battery posts.
NUT
CONNECTOR
TERMINAL RING
BOLT
7
4/1/2011 3:37:10 PM