Technical Data - PowerBox Systems LightBox SR Instruction Manual

Table of Contents

Advertisement

Note: if the receiver is powered by a stabilised voltage (e.g. from a PowerBox
battery backer), the Cut Off Voltage is set at a point about 0.3 V – 0.4 V below
the stabilised voltage. For 5.9 V this would be a Cut Off Voltage of 5.6 V. How-
ever, a long power cable to the LightBox SR may necessitate a lower cut-off
threshold.

6. TECHNICAL DATA

Operating voltage RC- Input:
Power supply ext. Akku:
Current drain, running:
Current drain, stand-by:
Switched channels:
Maximum current load:
Maximum current load:
Signal input:
Dimensions:
Weight incl. patch-lead:
Temperature range:
10
4.0 V – 9.0 V
2.5 V – 13.0 V
19 mA
150 μA
4
1.2 A per channel
4.0 A total
PWM or serial
58 x 19 x 15 mm
22 g
-30 °C to +75 °C