SETPOINT CONTROL
Access the ADJUST menu by pressing and holding simultaneously for 1 second, the Item,
now show the word ADJUST in the top right corner.
View Menu (1 of 1)
Display
Press and release the Item button to advance to the OUTDR DSGN adjustment. Press and hold the
button until OFF is displayed.
Press and release the Item button to advance to the MIX TARGET adjustment. Use the
select the desired temperature. The MIX TARGET setting is set to the desired setpoint supply temperature.
Press and release the Item button to advance to the units adjustment. Use the
the scale to °F or °C.
To exit the ADJUST menu, press and release the Item button to advance to the ESC item. Then
either press the
or
button, or leave the buttons alone for 20 seconds.
Current outdoor air temperature as measured by the outdoor
sensor. This is also the default display for the control.
(OUTDR DSGN ≠ OFF)
Current room air temperature as measured by the indoor sensor.
B1
(Indoor Sensor is present)
Current mixed supply water temperature as measured by the
B3
mixing sensor
B1
Target mixed supply is the temperature the control is currently
B2
trying to maintain at the mixing sensor.
B3
Current boiler temperature as measured by the boiler sensor.
(Boiler sensor is present)
Description
15 of 20
and
buttons. The display will
or
button to
or
button to set
Range
-67 to 149°F
(-55 to 65°C)
23 to 113°F
(-5 to 45°C)
14 to 266°F
(-10 to 130°C)
---, 14 to 266˚F
(---, -10 to 130˚C)
14 to 266°F
(-10 to 130°C)
© 2003
D 360e - 06/03