Trotec TTK 400 Original Instructions Manual

Trotec TTK 400 Original Instructions Manual

Hide thumbs Also See for TTK 400:

Advertisement

Quick Links

TTK 400
EN
ORIGINAL INSTRUCTIONS
DEHUMIDIFIER

Advertisement

Table of Contents
loading

Summary of Contents for Trotec TTK 400

  • Page 1 TTK 400 ORIGINAL INSTRUCTIONS DEHUMIDIFIER...
  • Page 2: Table Of Contents

    • Check accessories and connection parts for possible Information marked with this symbol helps you to carry damage prior to every use of the device. Do not use any out your tasks quickly and safely. defective devices or device parts. dehumidifier TTK 400...
  • Page 3 Trotec. • Only transport the device in an upright position with an emptied condensation tank or drain hose. Intended use •...
  • Page 4 For this reason, air-conditioning or by Trotec. always make sure to empty the container in time. Safety signs and labels on the device To do so, the condensate discharge line must be laid with a continuous decline all the way to the drain.
  • Page 5 Hold onto the mains plug while pulling the power cable out of the mains socket. Warning Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications! dehumidifier TTK 400...
  • Page 6: Information About The Device

    Two feet with rubber buffers prevent the device from rolling away. The device can reduce the relative humidity of a room to approx. 35 %. Because of the heat radiation generated during operation, the room temperature may rise slightly. dehumidifier TTK 400...
  • Page 7: Transport And Storage

    • with a cover to protect it from invasive dust, if necessary Feet with rubber buffers • Place no further devices or objects on top of the device to Condensation drain hose connection prevent it from being damaged. Air inlet with slot for air filter dehumidifier TTK 400...
  • Page 8: Assembly And Installation

    • Only position the device in rooms where there is no source of ignition (e.g. open flames, an active gas appliance or an electric heater). • Set the device up in an upright and stable position. dehumidifier TTK 400...
  • Page 9 T T K 2. Make sure that the condensation drain hose is properly connected to the device and free of damage. ð The device can also be operated with a condensate pump. Contact your Trotec customer service. dehumidifier TTK 400...
  • Page 10: Operation

    Dehumidification is briefly interrupted during defrosting. The fan keeps running. The duration of the defrost process can vary. Do not switch off the device during automatic defrost. Do not remove the mains plug from the mains socket. dehumidifier TTK 400...
  • Page 11: Available Accessories

    Maintenance). If the condenser is dirty, have it residual fluid from it. cleaned by a specialist company or by Trotec. • Clean the device according to the Maintenance chapter. • The device might carry out an automatic defrost. During •...
  • Page 12: Maintenance

    10. Date: ........11. Date: ........12. Date: ........Signature: ........Signature: ........Signature: ........Signature: ........13. Date: ........14. Date: ........15. Date: ........16. Date: ........Signature: ........Signature: ........Signature: ........Signature: ........dehumidifier TTK 400...
  • Page 13 Warning of electrical voltage Tasks which require the housing to be opened must only be carried out by authorised specialist companies or by Trotec. Note Install a 'No smoking sign' in the working area. Refrigerant circuit...
  • Page 14 T T K 2. Keep the four screws safe for later use. 3. Lift the housing cover off the device. 4 0 0 T T K 4 0 0 T T K 4. Carefully set the housing aside. dehumidifier TTK 400...
  • Page 15 • Reconnect the device to the mains. If you do not intend to use the device for a considerable time: • Store the device according to the Storage chapter. 7. Finally retighten all screws. 4 0 0 T T K dehumidifier TTK 400...
  • Page 16: Technical Annex

    Sound pressure level (at a distance of 56 dB(A) 3 m) Dimensions (length x width x height) 480 x 525 x 820 mm Minimum distance to walls and other objects A: top 50 cm B: rear 300 cm C: side 50 cm D: front 60 cm Weight 44 kg dehumidifier TTK 400...
  • Page 17 Refrigerant circuit Legend Definition Rotary compressor Pressureswitch Finned Tube Heat Exchanger Filter drier Capillary tube dehumidifier TTK 400...
  • Page 18 Circuit diagram dehumidifier TTK 400...
  • Page 19 TTK 400...
  • Page 20 TTK 400...
  • Page 21 Nut for M20 Cable grand Evap/Cond assembly cpl. Capacitor 35 μF Defrost stat Pressure sensitive switch EleTop Cover Loom Electrical panal assambly Compressor Cpl. ctrical Panel - sheetmental assembly Timer block 12 Way Saddle washer 25mm Manual Relay Handle dehumidifier TTK 400...
  • Page 22: Disposal

    EC Machinery Directive 2006/42/EC, Annex II, Part 1, Heinsberg, 14.05.2020 Section A Herewith, we – Trotec GmbH– declare that the machinery Detlef von der Lieck, Managing Director designated below was developed, constructed and produced in compliance with the requirements of the EC Machinery Directive in the version 2006/42/EC.
  • Page 23 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...

Table of Contents