Observe the personnel qualifications! Intended use Danger! Only use the device TTK 400 as a mobile industrial dryer for drying The device can cause injuries if it falls over! Tilt the and dehumidifying room air, while adhering to and following the device only slightly and move it carefully.
Air filter Rubber feet Condensation drain hose Air outlet Mains power cable Mains switch Standard scope of delivery • TTK 400 with bar handle • Air filter • Condensation drain hose • Operating manual Optional accessories • Hygrostat • Condensate pump •...
Page 5
To determine the precise power consumption, an optionally available energy cost gauge can be connected between the construction dryer and the power source. Contact your Trotec customer service. Operating Manual – Dehumidifier TTK 400...
Page 6
Refrigerant circuit diagram PROCESS PORT SOLENOID VALVE COMP EVAPORATOR CONDENSER DRIER Circuit diagram INTERLOCK INTERLOCK CYCLE FAULT LAMP CONT FAN MODE SWITCH Operating Manual – Dehumidifier TTK 400...
• with a plastic cover to protect it from invasive dust, if neces- sary. • The storage temperature is the same as the range given for the operating temperature in the chapter Technical data. Operating Manual – Dehumidifier TTK 400...
• When using a generator, ensure that the generator supplies at least 4 kW (The device's start-up current can exceed the nom- inal current by four or five times. Also note this fact when using several devices at one generator). Operating Manual – Dehumidifier TTK 400...
Page 10
2. Depending on the application, position the end of the conden- sation drain hose as follows: – Place a sufficiently dimensioned container (at least 90 litres) beside the device and insert the hose end. Check the filling level of the container regularly. 16x1 mm Operating Manual – Dehumidifier TTK 400...
Page 11
Depending on the air temperature and the relative humidity, the evaporator fins may freeze. The hot gas automatic defrost installed in the device switches back on as needed. Dehumidifica- tion mode is briefly interrupted during defrosting. Operating Manual – Dehumidifier TTK 400...
• Have the electrical equipment checked by a specialist compa- The device gets very warm, is loud or loses power: ny for cooling and air-conditioning or by Trotec. • Check the air inlets and air filter for dirt. Remove external dirt.
Page 14
The corners and edges of the air filter must not be deformed or rounded. Before reinserting the air filter, make sure that it is undamaged and dry! Read the chapter Maintenance intervals and replace the air filter in due time! Operating Manual – Dehumidifier TTK 400...
Page 15
Cleaning the inside with compressed air Operating Manual – Dehumidifier TTK 400...
Page 16
7220000195 dryer molecular sieve SD622954 spring (thermal overload) 7220000358 capillary tubes 0.090" OD x 0.052 ID x 64" SD622955 nut and bolt set SD364151 handle SD622956 rubber washer SD533251 user manual 7242000920 top cover Operating Manual – Dehumidifier TTK 400...
Page 17
Spare part SD512050 drip tray 7140000928 defrost control stat 7140000353 run capacitor 30 μF 440 V SD073150 hard start cap/relay 7130000918 rotary switch 2 pole on/off SA356403 loom assembly AX SD369350 pipe insert bung Operating Manual – Dehumidifier TTK 400...