TTK 120 E / TTK 122 E
EN
OPERATING MANUAL
DEHUMIDIFIER

Advertisement

Table of Contents
loading

Summary of Contents for Trotec ttk 120 e

  • Page 1 TTK 120 E / TTK 122 E OPERATING MANUAL DEHUMIDIFIER...
  • Page 2: Table Of Contents

    Warns of a hazard which can lead to per- sonal injury. Caution! Warns of a hazard which can lead to damage to property. The current version of the operating manual can be found at: www.trotec.de Operating Manual – Dehumidifier TTK 120/122 E...
  • Page 3: Information About The Device

    Device depiction Information about the device Description of the device This device uses the principle of condensation to auto- matically dehumidify rooms. The fan sucks damp room air through the air inlet (6), the air filter (4), the evaporator and to the condenser located behind it.
  • Page 4: Technical Data

    Technical data Parameter Value TTK 120 E TTK 122 E Dehumidifying capacity, max. 30 l / 24 h 40 l / 24 h Operating temperature 9-35 °C 9-35 °C Operating range for relative humidity 40-100 % 40-100 % Air flow rate, max.
  • Page 5 Circuit diagram – TTK 120 E Marking Meaning electronic card (power) humidity/temperature sensor card electronic card (control) humidity/temperature sensor evaporator sensor compressor thermal cutout RY102 compressor relay RY104 fan relay motor-driven compressor tank full microswitch tray presence microswitch S301 signal key for the humidity/room temperature detected...
  • Page 6 Circuit diagram – TTK 122 E Marking Meaning electronic card (power) humidity/temperature sensor card electronic card (control) humidity/temperature sensor evaporator sensor compressor thermal cutout bypass valve coil RY101 bypass valve coil relay RY102 compressor relay RY104 fan relay motor-driven compressor tank full microswitch tray presence microswitch S301...
  • Page 7: Safety

    • Only transport the device in an upright position companies for cooling and air-conditioning or by with an emptied condensation tank. ® TROTEC • Dispose of the collected condensation. Do not drink it. There is a risk of infection! Residual risks...
  • Page 8: Transport

    Caution! • with a plastic cover to protect it from invasive dust, if necessary. To avoid damages to the device, never operate the device without an air filter in- • The storage temperature is the same as the range serted! given for the operating temperature in the chapter Technical Data.
  • Page 9 • When positioning the device in wet areas such as Operating elements laundries, bath rooms or the like, secure the de- vice locally with an RCD (Residual Current protec- tive Device) which complies with the appropriate regulations. • Ensure that extension cords are completely un- rolled.
  • Page 10 Start procedure Switch device on Insert air filter 1. Ensure that the condensation tank is empty and inserted correctly. Otherwise, the device will not operate! 2. Insert the mains plug into a properly secured mains power socket. 3. Switch the device on at the power button (18). Note! In order to protect the compressor from damages, the device can only be switched in again 3 min-...
  • Page 11 If the room temperature is less that 5 °C, switch the device off. Note! If the evaporator of the TTK 120 E is frozen, the device switches the compressor off, so that the iced surface of the evaporator can defrost in the ambient air.
  • Page 12 Operation with hose attached to the condensation plug 1/2″ Shut down procedure 1. Switch the device off at the power button (see chapter Operating elements). 2. Do not touch the mains plug with wet or damp hands. 3. Remove the mains plug from the mains socket. 4.
  • Page 13: Errors And Faults

    If the inside of the device is dirty, have it cleaned • Have the electrics checked by a specialist compa- ® by a specialist company for cooling and air-condi- ny for cooling and air-conditioning or by TROTEC ® tioning or by TROTEC The device runs but forms no condensation: Does your device still not operate correctly after •...
  • Page 14: Maintenance

    Maintenance Maintenance intervals at least at least at least before every when at least Maintenance and care interval every 2 every 4 every 6 start necessary annually weeks weeks months empty condensation tank check air inlets and outlets for dirt and foreign objects and clean if necessary clean housing visually check the inside of the device for dirt...
  • Page 15 4. If you see a thick layer of dust, have the inside of the device cleaned by a specialist company for ® cooling and air-conditioning or by TROTEC 5. Put the air filter back in. Operating Manual – Dehumidifier TTK 120/122 E...
  • Page 16 Cleaning the air inlets and the air filter Caution! Ensure that the air filter is not worn or damaged. The corners and edges of the air filter must not be rounded or mis- shaped. Before reinserting the air filter, ensure that it is dry and is not damaged! Read the chapter Maintenance intervals and replace the air filter in due time!
  • Page 17: Disposal

    (see chapter Technical marking is found on the device nameplate. Data). Dispose of the cooling agent/oil mixture appro- priately and according to the national regulations. Manufacturer: Trotec GmbH & Co. KG Grebbener Straße 7 D-52525 Heinsberg Phone: +49 2452 962-400...
  • Page 20 Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-0 +49 2452 962-200 info @ trotec.com www.trotec.com...