Alarm E-Mail - Bosch MIC IP ultra 7100i User Manual

Hide thumbs Also See for MIC IP ultra 7100i:
Table of Contents

Advertisement

MIC IP ultra 7100i │ MIC IP starlight 7100i
Do not use any special characters, for example &, in the name. Special characters are not
supported by the system's internal management.
Signal Ranges
You can exclude particular signal ranges in order to avoid false alarms. For this reason the
total signal is divided into 13 tonal ranges (mel scale). Check or uncheck the boxes below the
graphic to include or exclude individual ranges.
Threshold
Set up the threshold on the basis of the signal visible in the graphic. You can set the threshold
using the slide control or, alternately, you can move the white line directly in the graphic using
the mouse.
Sensitivity
You can use this setting to adapt the sensitivity to the sound environment. You can effectively
suppress individual signal peaks. A high value represents a high level of sensitivity.
7.4

Alarm E-Mail

As an alternative to automatic connecting, alarm states can also be documented by e-mail. In
this way it is possible to notify a recipient who does not have a video receiver. In this case, the
camera automatically sends an e-mail to a previously defined e-mail address.
Send alarm e-mail
Select On if you want the unit to automatically send an alarm e-mail in the event of an alarm.
Mail server IP address
Enter the IP address of a mail server that operates on the SMTP standard (Simple Mail
Transfer Protocol). Outgoing e-mails are sent to the mail server via the address you entered.
Otherwise leave the box blank (0.0.0.0).
SMTP port
Select the appropriate SMTP port.
SMTP user name
Enter a registered user name for the chosen mailserver here.
SMTP password
Enter the required password for the registered user name here.
Format
You can select the data format of the alarm message.
Caution!
When a cellphone is used as the receiver, make sure to activate the e-mail or SMS function,
!
depending on the format, so that these messages can be received.
You can obtain information on operating your cellphone from your cellphone provider.
Image size
Select the appropriate image size: Small, Medium, Large, 720p, 1080p, Best possible.
Attach JPEG from camera
Click the checkbox to specify that JPEG images are sent from the camera. An enabled video
input is indicated by a check mark.
Bosch Security Systems
Standard (with JPEG) E-mail with attached JPEG image file.
SMS E-mail in SMS format to an e-mail-to-SMS gateway (for example to send an alarm by
cellphone) without an image attachment.
User Manual
Alarm | en
51
2020-11 | 1.4 |

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mic ip starlight 7100iMic inteox 7100iMic ip fusion 9000i

Table of Contents