TROUBLESHOOTING

Error Messages

E1
Coil temperature sensor error
E2
Error of the indoor temperature sensor
Frost protection function: If the coil temperature is too low, the appliance is
E4
switched off. If the temperature rises above 8 °C, the protection is released and
the previous operating state is restored.
FL
Water full - empty excess water
Problem
Air conditioner will
not operate at all
Unit is not starting
when pressing
ON/OFF
Air is blowing out,
but the cooling isn't
very effective
Noise or vibration
Possible Cause
Power is not turned on at the
wall.
Fuse has burnt out.
Start up timer hasn't been
triggered.
Unit was just recently turned
off and the compressor is
cooling down.
Room temperature is lower
than the setting temperature.
Temperature setting is
incorrect.
Air filter is blocked with dust.
Air inlet or outlet is blocked.
Air-conditioner has been
turned on inside a very hot
room.
Cooling capacity is insufficient
Doors or windows are open.
Ground is not level or flat
enough.
Possible Solution
Switch the power on at wall outlet.
Replace the fuse.
Wait or delete the original setting.
Wait for three minutes before
attempting to start again.
Reset the temperature.
Set the proper temperature, making
sure the temperature set is lower than
the ambient temperature.
Clean the air filter.
Remove the obstacle.
Allow additional time for the air-
conditioner to remove all of the heat
stored in the room.
If the room being cooled down is too
large the air-conditioner, then it may
not have the power required to do the
task.
Close the doors and windows.
Move the air-conditioner to a flatter,
more level area of flooring.