Download Print this page

Graco 222461 Instructions-Parts List Manual page 8

Electronic lubricant valve, metered or unmetered hi-flow in-line dispense valves, without meter, with electronic meter measures in gallons/quarts/pints, measures in liters

Advertisement

Service – Electronic Meter
CAUTION
To avoid damaging the electronic components of
the control:
D Always use the personal grounding strap
provided with a replacement metering unit
and electronic control when you remove the
cover (1), and while you replace the parts.
This strap protects the electronic
components from damage due to
electrostatic discharge.
D Do not lay anything on the control.
D Be sure the open side of the control faces up
if you lay it down.
D Do not twist or force parts. Align parts
properly as instructed.
WARNING
To reduce the risk of a fire, explosion, and serious
burns to the body, handle and dispose of a used
electronic control (103) properly.
The electronic control contains a lithium battery.
Do not short circuit, charge, force over discharge,
disassemble, crush, penetrate, incinerate, or heat
the battery to a temperature exceeding 185_ F
(85_ C). Any misuse or abuse of the battery may
cause it to leak or explode.
Use only genuine Graco replacement parts. The use of any other parts may impair the intrinsic safety of this
meter. This could result in a failure, which could cause serious bodily injury and/or substantial property
damage.
Fig. 7
8
8
308113
WARNING
DETAIL A
106
104
02175C
1. Relieve the pressure.
WARNING
To reduce the risk of serious injury, when you are
instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 7.
2. Attach the disposable grounding wrist strap to your
wrist. Connect the adhesive-backed copper foil at
the other end to any convenient electrical ground,
such as the grounding screw or metal case of a
grounded electrical outlet.
3. Lift the bottom edge of the black cover (101) away
from the meter (102), and pull the cover off.
Remove and discard the screws (106). Lift off the
electronic control (103). Remove and discard the
large o-ring (104).
4. Install a new metering unit (102) and/or electronic
control (103). Install the large o-ring (104) over the
lip on top of the metering unit (102). Align the
notch on the side of the electronic control (103)
with the notch on the side of the metering unit
(102). Install the new screws (106), and torque
them oppositely and evenly to 4 to 6 in-lb (0.45 to
0.68 N-m).
5. Install the cover so the rolled-in edges are parallel
with the inlet fluid passage of the metering unit.
101
106
103
102
104
02174C

Advertisement

loading

This manual is also suitable for:

222561222471222441222571222541