Download Print this page

Graco 222461 Instructions-Parts List Manual page 5

Electronic lubricant valve, metered or unmetered hi-flow in-line dispense valves, without meter, with electronic meter measures in gallons/quarts/pints, measures in liters

Advertisement

Operation – Electronic Meter
CAUTION
Never operate the meter with the black plastic
cover removed. The cover protects the meter from
damage due to impact. Meters are factory sealed
to keep moisture and dirt out. See the Service
section before you service the meter.
CAUTION
To prevent line contamination, which can cause
equipment malfunction or damage, flush the lines
before you install this equipment in the system.
To Activate the Digital Display
Press the RESET key pad to clear the meter before
you start a new dispense cycle. This is the best way
to activate the meter, because it also clears the
quantity of the last dispense cycle.
The digital display can also be activated by pressing
the TOTAL key pad or by running fluid through the me-
ter. See Fig. 1.
NOTE: The digital display of the meter goes blank
after approximately two minutes of non-use.
Function of TOTAL
When the digital display is blank, press and release the
TOTAL key pad to display the quantity of the last dis-
pense cycle. See Fig. 2.
To see the accumulated total of fluid dispensed
through the meter, press and hold the TOTAL key pad.
The accumulated total is shown in gallons for the
gallon/quart/pint meter, and in liters for liter meter. The
meter can accumulate a running total of up to 19999
gallons (or liters) dispensed before returning to zero.
See Fig. 3.
Function of RESET
Press the RESET key pad to clear the quantity of the
last dispense cycle and return the digital display to all
zeros. See Fig. 1.
To Change the Measurement Units
(gallon/quart/pint meter only)
The meter is factory-set to dispense in quarts. To
change the measurement units, press and hold the
RESET key pad until the measurement unit on the
right side of the digital display is flashing. Then press
the TOTAL key pad until the desired measurement unit
is shown. Release both key pads. See Fig. 4.
CAUTION
To be sure the proper amount of fluid is dispensed,
always use the same measurement unit for a par-
ticular fluid.Units should be changed only by autho-
rized employees.
For Maximum Dispensing Accuracy
(gallon/quart/pint meter only)
Set the meter to dispense in pints or quarts when dis-
pensing 1 gallon or less.
Always press the RESET key pad to clear the meter
before a new dispense cycle.
GRACO
TOTAL
Press RESET to
clear
DIGITAL DISPLAY
Fig. 1
EXAMPLE OF TOTAL FOR
LAST DISPENSE CYCLE
Fig. 2
EXAMPLE OF ACCUMULATED TOTAL
Fig. 3
PINTS
QUARTS
GALLONS
EXAMPLE OF MEASUREMENT UNITS
Fig. 4
GAL
RESET
QTS
GAL
PTS
QTS
GAL
5