Mains Supply; Servicing; Cleaning The Turbine; Setting The Switch Point - Daewoo DAEQDP Series User Manual

Table of Contents

Advertisement

3. MAINS SUPPLY

Before starting up the pump make sure that:
- The pump is to be powered by a residual differential current device, with a rated operating diffe-
rential current not exceeding 30 mA.
- The mains supply voltage matches the voltage indicated on the pump identification plate (230-
v~/50Hz).
Ask your specialist electrician for advice.
Make sure that the fuse protecting the power outlet is at least 6 amps.
Warning!
If the power cable is damaged, it must be replaced by a professional to avoid the risk of danger.
Commissioning
After installing the pump as indicated in these instructions, it is ready to work.

4. SERVICING

Disconnect the power outlet before making any adjustments or performing servicing operations.
The pump does not require any specific maintenance but for longer life we recommend that you
check and clean the area in which the pump is installed (every three months, for example).
For temporary use, clean the pump with clean water after using it.

5. CLEANING THE TURBINE

(Remove the plug from the power outlet before cleaning operations start)
If there are heavy deposits in the pump body, the lower part must be dismantled as follows:
1. Remove the 4screws from the lower side of the suction basket.
2. Detach the suction basket from the body of the pump.
3. Clean the pump with clean water.
Warning! Do not put down the pump on the turbine nor hold it by this point either!
4. For reassembly, repeat the above operations in reverse order.

6. SETTING THE SWITCH POINT

(The float switch point can be set by adjusting the notches.
Check the following points before switching on:
·The float switch must be installed so that the switch point level can be reached easily with very little
effort. Make sure of this as follows: immerse the pump in a container full of water and lift the float
switch carefully by hand, then lower it. You can thereby check that the pump starts and stops.
·Make sure that the gap between the head of the float switch and the float switch anchorage device
is not too small. If the gap is not wide enough, perfect operation is not guaranteed.
·Concerning adjustment, make sure that the float switch does not touch the floor before the pump
has stopped. Warning! Risk of running dry.
·To modify the starting level, slide the float cable into the notch provided for the purpose on the
handle.