Advertisement

Quick Links

WATER PUMPS
GAE 50-80-100
USER´S MANUAL
Manufactured under license of Daewoo International Corporation, Korea

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GAE 50 and is the answer not in the manual?

Questions and answers

Summary of Contents for Daewoo GAE 50

  • Page 1 WATER PUMPS GAE 50-80-100 USER´S MANUAL Manufactured under license of Daewoo International Corporation, Korea...
  • Page 2: Table Of Contents

    English T ABLE OF CONTENTS 1.0 - OPERATION SAFETY 1.1 - Operation Safety 2.0 - COMPONENTS 3.0 - PRE-OPERATION INSPECTION 3.1 - Engine Oil Check 3.2 - Fuel Level Check 3.3 - Air Filter Check 3.4 - Hose Connections 4.0 - OPERATION 4.1 - Pump Placement 4.2 - Priming Water 4.3 - Starting Trash Pump...
  • Page 3: Operation Safety

    English 1.0 - SAFETY PRECAUTIONS 1.1 - Operation Safety • Always perform a pre-operation check before starting the engine. • Properly clean and maintain the equipment. • Operate the Trash Pump according to instructions for safe and dependable service. • Read user manual carefully before operating this product! Failure to do so may result in serious harm to the user and to the equipment.
  • Page 4: Components

    English 2.0 IDENTIFICATION OF COMPONENTS Outlet Port Trash Pump...
  • Page 5: Engine Oil Check

    English 3.0 - PRE-OPERATING PROCEDURE Inspect all components for damage and to ensure that none are missing. If you require a replacement, do not operate this tool until all parts are present and in proper working order. Do not modify or create accessories for this equipment. Using modified components may result in damage and may void the warranty.
  • Page 6: Fuel Level Check

    English 3. If necessary, add engine oil - Open oil inlet located opposite the recoil starter handle. Remove the dipstick and pour in the supplied oil with a funnel. Do not operate without oil. Reservoir can hold maximum 20 fl.oz of 10W30 oil - do not over fill. Engine oil is a major factor affecting engine performance and service life.
  • Page 7: Air Filter Check

    English Gasoline is highly flammable and explosive under certain conditions. Refuel in a well-ventilated area with the engine stopped. Do not smoke or allow open flames or sparks in the area where the Trash Pump is being refueled or where gasoline is stored.
  • Page 8: Hose Connections

    English 3.4 - Hose Connections 1. Insert adapters into each end of the suction and discharge hoses. 2. Attach O-Rings to the adaptors. 3. Tighten the hose clamp around the discharge hose. 4. Insert strainer into the suction hose and tighten the hose clamp around the hose.
  • Page 9: Operation

    English 4.0 - OPERATION 4.1 - Pump Placement Placement is an important step in safely operating this product. 1. Refer to diagram for proper placement instructions. 2. Ensure that the suction head is less than the discharge head. 3. Increasing the discharge head will decrease output. 4.
  • Page 10: Priming Water

    4.2 - Priming Water Make sure to prime the pump with water prior to operating it. Priming creates a vacuum that helps to start the flow of water. 1. Unscrew the primer cap and insert the neck of the water container into the opening.
  • Page 11: Stopping The Engine

    English 3. Grasp the recoil starter handle and pull it until the engine starts. Do not allow the recoil starter to snap back. Return it slowly by hand 4. Push the choke lever to the OPEN position as the engine warms up. The choke is used to provide the proper mixture when the engine is cold.
  • Page 12: Maintenance

    5.1 - Importance of Maintenance Proper maintenance ensures safe, economical and trouble-free operation. Improper maintenance may cause the Trash Pump to malfunction and can lead to serious injuries. Contact daewoo Power Customer Support if you have any maintenance questions. 5.2 - Maintenance Schedule...
  • Page 13: Oil Maintenance

    English 5.3 - Oil Change and Oil Drainage Used motor oil can cause skin irritations if left in long-tern contact with skin. Wash hands thoroughly with soap and water after handling oil. Do not dispose of used oil in drains or on soil. Local service shops provide environmentally-friendly disposal methods.
  • Page 14: Air Filter Service

    English 5.4 - Air Filter Service Using gasoline or other flammable solvents can cause a fire or explosion. Do not use these to clean the air filter. Do not operate this product without an air filter.
  • Page 15: Spark Plug Service

    English 5.5 - Spark Plug Service Do not rinse spark plug in water. Follow guidelines and be careful not to overtighten the spark plug. Tighten ½ turn when installing a new spark plug. Tighten ¼ turn when re-installing an old spark plug. 1.
  • Page 16: Fuel Sediment Cup

    English 5.6 - Fuel Sediment Cup Service 1. Switch fuel valve to the OFF position. 2. Unscrew the sediment cup using a wrench and remove the O-ring. thoroughly. 4. Place the O-ring in the fuel valve, then attach sediment cup. Tighten securely.
  • Page 17: Impeller Cleaning

    English 5.8 - Impeller Cleaning Impeller cleaning is important when storing pump for long periods of time. It is also advisable as part of regular maintenance checks. QUICK METHOD 1. Fill pump with fresh water through primer opening. 2. Start pump and allow it to run for up to 8 minutes or until water evaporates upon contact with engine block.
  • Page 18: Transportation

    English When reinstalling the casing, ensure that the rubber seal is properly secure all around the perimeter of the opening. 5.9 - Transportation Engine and exhaust can become hot. Avoid contact due to risk of burns and fires. Allow engine to cool before transporting unit. Do not drop or strike the pump during transport.
  • Page 19: External Parts Cleaning

    English 5.11 - External Parts Cleaning Keeping the external parts clean can prevent debris build-up and ensure easy access during maintenance. Do not use a pressure washer to clean this product. Delicate electrical components may be damaged. 1. Place unit in a well-lit area areas around the gas tank and oil ports.
  • Page 20: Specifications

    English 7.0 - SPECIFICATIONS GAE50 GAE80 GAE100 Discharge Port Diameter 50mm 80mm 100mm Suction Port Diameter 50mm 80mm 100mm Maximum Discharge 30m /h 45m /h 69m /h Maximum Lift Maximum Suction Operating Temperature 0°-40°C Range 7 HP, Single Cylinder, forced air cooling, 4-stroke, Type OHV 25 deg tilt Displacement (cm...
  • Page 21 English WARRANTY The manufacturer warrants the product against faulty materials and workmanship for a period of 24 months from the date of first purchaser to the original purchaser. The warranty is applicable when the product is used in a “home owner” application. If products are used for commercial or professional purposes, the warranty period is for 12 months from the date of first purchase.
  • Page 22 Manufactured under license of Daewoo International Corporation, Korea...

This manual is also suitable for:

Gae 80Gae 100

Table of Contents