schmersal SLC440COM Series Operating Instructions Manual

schmersal SLC440COM Series Operating Instructions Manual

Safety light curtain / safety light grid
Hide thumbs Also See for SLC440COM Series:
Table of Contents

Advertisement

Quick Links

Operating instructions
Safety light curtain / safety light grid
Version 3.0
Original
Content
1
About this document
11
Function                                            1
12
Target group: authorised qualified personnel                1
13
Explanation of the symbols used                         1
14
Appropriate use                                       2
15
General safety instructions                              2
16
Warning about misuse                                 2
17
Exclusion of liability                                    2
2
Product description
21
Purpose                                             2
22
Bluetooth interface                                    2
23
Ordering code                                        2
24
Special versions                                      2
25
Included in delivery                                    2
26
Technical data                                        3
27
Response time (reaction time)                           3
28
Safety classification                                   4
29
Functions                                           4
291 Protective mode / Automatic                             4
292 Restart Interlock (operation)                             4
210 Self-test                                             4
211 Bluetooth                                            4
3
Parameterisation
4
Mounting
41
General conditions                                    5
42
Protection field and approach                            5
43
Alignment of the sensors                               6
44
Setting mode                                         6
441 Automatic setting mode                                6
442 Activating setting mode with 5-pin cable connection           6
45
Safety distance                                       6
46
Increasing the safety distance in the event of risk of a protection
field overlap                                          7
47
48
49
Accessories, included in delivery                         11
410 Optional accessory                                    11
5
51
52
53
6
61
62
63
64
65
7
71
72
8
81
82
9
91
92
Information on wireless interface                        15
10
EU Declaration of conformity
1. About this document
1.1 Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional
information
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine
EN
SLC440COM Series
SLG440COM Series
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLC440COM Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal SLC440COM Series

  • Page 1: Table Of Contents

    Operating instructions SLC440COM Series Safety light curtain / safety light grid SLG440COM Series 461 Minimum distance to reflecting surfaces                    8 Mounting                                            9...
  • Page 2 The interface is integrated into the receiver This technology, in conjunction with the Schmersal app 'SLC Assist', gives you access to Further technical information can be found in the Schmersal...
  • Page 3 Operating instructions SLC440COM Series Safety light curtain / safety light grid SLG440COM Series 2.6 Technical data 2.7 Response time (reaction time) Standards: EN 61496-1; EN 61496-2; The response time depends on the height of the protection field, the ISO 13849; EN 62061...
  • Page 4 Control category: up to 4 PFH value: 777 x 10 Download the Schmersal app SLC Assist from your app store to your SIL: up to 3 smartphone or tablet The app is available for both, iOS and Android Mission time:...
  • Page 5 Operating instructions SLC440COM Series Safety light curtain / safety light grid SLG440COM Series 3. Parameterisation 4. Mounting In parameter setting mode, individual adaptation of the operating 4.1 General conditions parameters can be carried out on the receiver The following guidelines are provided as preventive warning notices...
  • Page 6 Operating instructions SLC440COM Series Safety light curtain / safety light grid SLG440COM Series 4.3 Alignment of the sensors Calculation of the safety distance to ISO 13855 and ISO 13857 Procedure: 1 Emitter and receiver must be fitted parallel to each other and at the...
  • Page 7 Operating instructions SLC440COM Series Safety light curtain / safety light grid SLG440COM Series Calculation of the safety distance for the multi-beam light grid 4.6 Increasing the safety distance in the event of risk of a SLG440COM protection field overlap If an overlap of the protection field is possible, take care with...
  • Page 8: 461 Minimum Distance To Reflecting Surfaces                    8

    Operating instructions SLC440COM Series Safety light curtain / safety light grid SLG440COM Series Reaching through the protective area of a non-contact functioning guard system (extract ISO 13855) Height of the Height b of the upper edge of the protection area of the non-contact functioning guard system...
  • Page 9: Mounting                                            9

    Operating instructions SLC440COM Series Safety light curtain / safety light grid SLG440COM Series 4.7 Mounting The AOPD should be installed in such a way that interference with neighbouring safety light barriers / grids of the same type (AOPD) is excluded...
  • Page 10: Dimensions                                         10

    Operating instructions SLC440COM Series Safety light curtain / safety light grid SLG440COM Series 4.8 Dimensions 4.8.1 Dimensions emitter and receiver SLC440COM 4.8.2 Dimensions emitter and receiver SLG440COM All measurements in mm All measurements in mm 27,8 27,8 Type Type Beam...
  • Page 11: Accessories, Included In Delivery

    Operating instructions SLC440COM Series Safety light curtain / safety light grid SLG440COM Series 4.9 Accessories, included in delivery 4.10 Optional accessory Mounting kit MS-1100 Centre support MS-1110 The mounting kit consists of 4 pcs steel angles and 8 pcs fixing...
  • Page 12: Electrical Connection

    Operating instructions SLC440COM Series Safety light curtain / safety light grid SLG440COM Series 5. Electrical connection 5.1 Wiring diagram +24 VDC 0 VDC Protective mode / Automatic active: Delivery state (Pushbutton S1 not connected) Restart Interlock (manual reset) active: Refer to the chapter: operating mode activate restart interlock...
  • Page 13: Wiring Example With Safety Relay Module                  13

    Operating instructions SLC440COM Series Safety light curtain / safety light grid SLG440COM Series The colour codes are only valid for the cable types mentioned 5.2 Wiring example with safety relay module below "optional accessories" For UL evaluated products we do recommend to use the UL style cable 20549 6.
  • Page 14: 64 Half-Yearly Inspection                                 14

    7. Diagnostic 7.1 Status information 9. Appendix Signalisation of the status occurs at the receiver end cap 9.1 Contact Status display - receiver Consultancy / Sales: K.A. Schmersal GmbH & Co. KG Operating Display Description Möddinghofe 30 condition D-42279 Wuppertal...
  • Page 15 Operating instructions SLC440COM Series Safety light curtain / safety light grid SLG440COM Series 9.2 Information on wireless interface Information on wireless interface RED-Directive 2014/53/EU This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions:...
  • Page 16: Operating Instructions           Pages 1 To

    Authorised signature Klaus Schuster Christian Spranger Managing Director Managing Director The currently valid declaration of conformity can be downloaded from the internet at productsschmersalcom K.A. Schmersal GmbH & Co. KG Möddinghofe 30, 42279 Wuppertal Germany Phone: +49 202 6474-0 Telefax:...