schmersal SLC440COM Series Operating Instructions Manual

schmersal SLC440COM Series Operating Instructions Manual

Safety light curtain / safety light grid
Hide thumbs Also See for SLC440COM Series:

Advertisement

Quick Links

Operating instructions
Safety light curtain / safety light grid
Version 2.0
Operating instructions           pages 1 to 12
EN
Original
Content
1
About this document
11
Function                                            1
Target group: authorised qualiied personnel                1
12
13
Explanation of the symbols used                         1
14
Appropriate use                                       2
15
General safety instructions                              2
16
Warning about misuse                                 2
17
Exclusion of liability                                    2
2
Product description
21
Destination and use                                   2
22
Ordering code                                        2
23
Special versions                                      2
24
Included in delivery                                    2
25
Technical data                                        2
26
Response time (reaction time)                           3
Safety classiication                                   3
27
28
Functions                                           4
281 Protective mode / Automatic                             4
282 Restart Interlock (operation)                             4
283 Mode of operation - Restart Interlock - activate              4
29
Self-test                                             4
3
Mounting
31
General conditions                                    4
Protection ield and approach                            4
32
33
Alignment of the sensors                               5
34
Setting mode                                         5
341 Setting mode with cable connection 5-pole                 5
342 Setting mode with cable connection 4-pole                 5
35
Safety distance                                       5
351 Minimum distance to relecting surfaces                    6
36
Mounting                                            6
37
38
381 Included in delivery                                    8
4
41
42
43
5
51
52
53
Regular check                                        11
54
Half-yearly inspection                                  11
55
Cleaning                                            11
6
61
Status information                                     11
62
Fault diagnostic                                       11
7
71
Disassembly                                         11
72
Disposal                                            11
8
81
Contact                                             11
9
EU Declaration of conformity
1. About this document
1.1 Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear The operating
instructions must be available in a legible condition and a complete ver-
sion in the vicinity of the device
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only
Please make sure that you have read and understood these operat-
ing instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation
The machine builder must carefully select the harmonised standards to
be complied with as well as other technical specifications for the selec-
tion, mounting and integration of the components
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine
EN
SLC440COM
SLG440COM
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLC440COM Series and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal SLC440COM Series

  • Page 1: Table Of Contents

    Operating instructions SLC440COM Safety light curtain / safety light grid SLG440COM Dimensions                                          7 371 Dimensions transmitter and receiver SLC440COM            7 372 Dimensions transmitter and receiver SLG440COM            7 Fixing                                              8...
  • Page 2 Resolution 14 mm with a range of 03 m … 7 m Resolution 30 mm with a range of 03 m … 10 m Further technical information can be found in the Schmersal Resolution 35 mm with a range of 03 m … 7 m...
  • Page 3 Operating instructions SLC440COM Safety light curtain / safety light grid SLG440COM Transmitter, infrared emitted radiation SLC440COM Resolution 30 mm - to DIN EN 12198-1: Category 0 Protection field Beams (lines) Response Weight - to DIN EN 62471: free group height [mm] [Number] time [ms] [kg]...
  • Page 4 Operating instructions SLC440COM Safety light curtain / safety light grid SLG440COM 2.8 Functions 3. Mounting The system consists of a receiver and a transmitter For the described functions, no further switching elements are required 3.1 General conditions The following guidelines are provided as preventive warning notices The system has the following operating modes: to ensure a safe and appropriate handling These guidelines are an •...
  • Page 5 Operating instructions SLC440COM Safety light curtain / safety light grid SLG440COM 3.3 Alignment of the sensors If value S >= 500 mm, recalculate the distance: Procedure: 1 Transmitter and receiver must be fitted parallel to each other and at (2) S = 1600 mm/s * T + 8 (d - 14) [mm] the same height 2 Choose the operating mode "Automatic"...
  • Page 6 Operating instructions SLC440COM Safety light curtain / safety light grid SLG440COM Safety distance to the hazardous area Safety distance a a [mm] 1000 Transmitter Direction from which the hazardous area is accessed Hazardous point D [m] 0 3 5 Receiver Calculate the minimum distance to reflecting surfaces as a function of Command device the distance with an aperture angles of ±...
  • Page 7: Dimensions                                          7

    Operating instructions SLC440COM Safety light curtain / safety light grid SLG440COM 3.7 Dimensions 3.7.2 Dimensions transmitter and receiver SLG440COM All measurements in mm 3.7.1 Dimensions transmitter and receiver SLC440COM All measurements in mm 27,8 27,8 Type Type Protected Mounting Total Beam Mounting Total...
  • Page 8: Fixing                                              8

    Operating instructions SLC440COM Safety light curtain / safety light grid SLG440COM 3.8 Fixing 3.8.2 Optional accessories 3.8.1 Included in delivery Centre support MS-1110 Mounting kit consists of 2 steel angles and 4 spacers for central fixing Mounting kit MS-1100 The mounting kit consists of 4 steel angles and 8 fixing screws (Type Torx plus 10IP) 27,8 54,3...
  • Page 9: Electrical Connection

    Operating instructions SLC440COM Safety light curtain / safety light grid SLG440COM 4. Electrical connection 4.1 Wiring example SLC/SLG440COM Earth connection Protective mode / Automatic active: K1, K2: Relay for processing the switching outputs Delivery state (Command device button S1 not connected) OSSD 1,OSSD 2 Command device pushbutton for restart (optional) Restart Interlock (manual reset) active:...
  • Page 10: Wiring Example With Safety-Monitor Module                10

    Operating instructions SLC440COM Safety light curtain / safety light grid SLG440COM The colour codes are only valid for the cable types 4.2 Wiring example with safety-monitor module mentioned below "optional accessories" For UL evaluated products we do recommend to use the UL style cable 20549 5.
  • Page 11: Regular Check

    The following items must be checked every six months or when a ma- 8.1 Contact chine setting is changed Consultancy / Sales: K.A. Schmersal GmbH & Co. KG 1 Machine stops or does not inhibit any safety function 2 No machine modification or connection change, which affects the Industrielle Sicherheitsschaltsysteme safety system, has taken place Möddinghofe 30...
  • Page 12 Managing Director Managing Director The currently valid declaration of conformity can be downloaded from the internet at wwwschmersalnet K. A. Schmersal GmbH & Co. KG Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal Phone:...

This manual is also suitable for:

Slg440com series

Table of Contents